Literature DB >> 30100293

Muscle thickness and echo intensity measurements of the rectus femoris muscle of healthy subjects: Intra and interrater reliability of transducer tilt during ultrasound.

Hiroshi Ishida1, Tadanobu Suehiro2, Keita Suzuki2, Susumu Watanabe2.   

Abstract

This study aimed to assess the intra and interrater reliability of transducer tilt during the ultrasound (US) measurements of the muscle thickness and the echo intensity of the rectus femoris muscle (RF). Fourteen healthy male subjects (20.8 ± 0.8 years) participated in this study. The transducer tilt was measured using a digital angle gauge (°) during US. Two experimenters took two images to measure the muscle thickness (mm) and the echo intensity (a.u.: arbitrary unit). The intra and interclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were also calculated. These measurements were immediately repeated. The ICC for the intrarater reliability for the transducer tilt, muscle thickness, and echo intensity were 0.96 (SEM: 0.9°, MDC: 2.6°), 0.99 (SEM: 0.4 mm, MDC: 0.1 mm), and 0.97 (SEM: 0.6 a.u. , MDC: 1.7 a.u.), respectively. The ICC for the interrater reliability for the transducer tilt, muscle thickness, and echo intensity were 0.40 (SEM: 4.0°, MDC: 11.1°), 0.96 (SEM: 0.7 mm, MDC: 2.0 mm), and 0.95 (SEM: 0.9 a.u. , MDC: 2.4 a.u.), respectively. The intrarater reliability of the transducer tilt was reliable, but the interrater reliability was questionable. Meanwhile, both the intra- and interrater reliability of the muscle thickness and the echo intensity were reliable.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Keywords:  Echo intensity; Muscle thickness; Reliability; Transducer; Ultrasound

Mesh:

Year:  2017        PMID: 30100293     DOI: 10.1016/j.jbmt.2017.12.005

Source DB:  PubMed          Journal:  J Bodyw Mov Ther        ISSN: 1360-8592


  4 in total

1.  Associations between physical fitness components with muscle ultrasound parameters in prepuberal children.

Authors:  Yesenia García-Alonso; Antonio García-Hermoso; Alicia M Alonso-Martínez; Mikel Izquierdo; Robinson Ramírez-Vélez; Gaizka Legarra-Gorgoñon
Journal:  Int J Obes (Lond)       Date:  2022-01-14       Impact factor: 5.095

2.  Influence of subcutaneous adipose thickness and dominance on reliability of quadriceps muscle quality in healthy young individuals.

Authors:  Jaquelini Betta Canever; Fábio Juner Lanferdini; Bruno Monteiro de Moura; Fernando Diefenthaeler; Kelly Mônica Marinho E Lima
Journal:  J Ultrasound       Date:  2021-09-14

3.  Intra-rater and inter-rater reliability of the process of obtaining cross-sectional area and echo intensity measurements of muscles from ultrasound images.

Authors:  Eric J Sobolewski; Leah D Wein; Jacquelyn M Crow; Kaitlyn M Carpenter
Journal:  J Ultrason       Date:  2021-03-08

4.  Ultrasound Imaging Analysis of the Lumbar Multifidus Muscle Echo Intensity: Intra-Rater and Inter-Rater Reliability of a Novice and an Experienced Rater.

Authors:  Maryse Fortin; Brent Rosenstein; Jerome Levesque; Neil Nandlall
Journal:  Medicina (Kaunas)       Date:  2021-05-20       Impact factor: 2.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.