Literature DB >> 30097073

Inductively Coupled Plasma Collision Cell Quadrupole Mass Spectrometric Determination of Extractible Arsenic, Cadmium, Chromium, Lead, Mercury, and Other Elements in Food Using Microwave-Assisted Digestion: Results from an FDA Interlaboratory Study.

Patrick J Gray1, William Cunningham1.   

Abstract

Background: An interlaboratory study was conducted to test U.S. Food and Drug Administration (FDA) Elemental Analysis Manual (EAM) Method 4.7, "Inductively Coupled Plasma-Mass Spectrometric Determination of Arsenic, Cadmium, Chromium, Lead, Mercury, and Other Elements in Food Using Microwave Assisted Digestion." Objective: The goal of the study was to demonstrate the performance of FDA EAM Method 4.7.
Methods: Fourteen laboratories participated in the collaborative study, including nine Food Emergency Response Network state laboratories and five federal FDA laboratories. Laboratories tested 8 labeled standard reference materials and 12 blinded foods: mayonnaise, dark chocolate, sunflower seeds, hamburger with cheese, brown rice flour (blinded reference material included as a test food), infant formula, canned smoked oysters, sardines in tomato paste, swordfish, mineral water, cinnamon, and a multivitamin. The blinded test foods represented every sector of the AOAC food triangle. Participants measured the mass fraction of each element in each sample in triplicate.
Results: Horwitz Ratio (HorRat) values were better than 1.5 for all As, Cd, Cu, Hg, Mo, Ni, Pb, and Se measurements when at least eight laboratories reported results greater than LOQ. The HorRat values were better than 1.5 for all Mn and Zn measurements except for the multivitamin and for all Cr measurements except for sunflower seeds, in which the nonhomogeneity was identified. The average HorRat value of the blinded test foods was 0.66 for results greater than LOQ (n = 4206). Conclusions: The study showed that the method performed satisfactorily as a standard method for extractible elemental analysis of food. Highlights: The method met or exceeded the performance expected.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30097073     DOI: 10.5740/jaoacint.18-0129

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  3 in total

1.  A survey of cannabinoids and toxic elements in hemp-derived products from the United States marketplace.

Authors:  Geoffrey A Dubrow; Rahul S Pawar; Cynthia Srigley; Jennifer Fong Sam; Christian Talavera; Christine H Parker; Gregory O Noonan
Journal:  J Food Compost Anal       Date:  2021-04-01       Impact factor: 4.520

2.  Temperature and pH affect copper release kinetics from copper metal foil and commercial copperware to food simulants.

Authors:  John L Koontz; Girvin L Liggans; Benjamin W Redan
Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess       Date:  2020-01-08

3.  Ammonium Pyrrolidine Dithiocarbamate-Modified CdTe/CdS Quantum Dots as a Turn-on Fluorescent Sensor for Detection of Trace Cadmium Ions.

Authors:  Yuan Yin; Qingliang Yang; Gang Liu
Journal:  Sensors (Basel)       Date:  2020-01-06       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.