Literature DB >> 30091715

Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients.

İsmail Özsoykal1, Ayşegül Yurt1, Kadir Akgüngör1.   

Abstract

PURPOSE: Size-specific dose estimates (SSDEs) are the latest focus of interest among medical physicists studying radiation dose to the patient in computed tomography (CT). This study aims to make conversions from CTDIvol to SSDE and investigate the relationship between mean SSDE (SSDE) and central SSDE (SSDEcenter) values for pediatric patients of different age groups undergoing chest, abdomen, and pelvis scans.
METHODS: In this retrospective study, we examined 105 consecutive pediatric CT exams of chest, abdomen, and pelvis (CAP) classified in 3 separate groups according to age: 0-5 years, 6-10 years, and 11-16 years. A MATLAB program was developed to determine SSDE values for each patient along 6 subregions: chest, abdomen, pelvis, chest and abdomen, abdomen and pelvis, and CAP. SSDE values derived over the slice at the center of each scan range (SSDEcenter) were also recorded. SSDE and corresponding SSDEcenter results were compared for each age group.
RESULTS: Root mean square differences (RMSD) between SSDE and SSDEcenter values ranged between 0.13 mGy and 2.1 mGy through all groups and subregions, corresponding to 1.2% and 11%, respectively.
CONCLUSION: In pediatric CT exams involving CAP region, CTDIvol and the water equivalent diameter at the middle of the scan range can be used to provide a reasonable estimate of mean SSDE with an RMSD of 11% at most.

Entities:  

Mesh:

Year:  2018        PMID: 30091715      PMCID: PMC6045513          DOI: 10.5152/dir.2018.17450

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  10 in total

1.  ICRU Report No. 87: Radiation dose and image-quality assessment in computed tomography.

Authors: 
Journal:  J ICRU       Date:  2012-04

2.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

3.  Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images.

Authors:  Jia Wang; Jodie A Christner; Xinhui Duan; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

5.  A method for describing the doses delivered by transmission x-ray computed tomography.

Authors:  T B Shope; R M Gagne; G C Johnson
Journal:  Med Phys       Date:  1981 Jul-Aug       Impact factor: 4.071

6.  Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter.

Authors:  Shuai Leng; Maria Shiung; Xinhui Duan; Lifeng Yu; Yi Zhang; Cynthia H McCollough
Journal:  Radiology       Date:  2015-02-25       Impact factor: 11.105

7.  Size-specific dose estimates for adult patients at CT of the torso.

Authors:  Jodie A Christner; Natalie N Braun; Megan C Jacobsen; Rickey E Carter; James M Kofler; Cynthia H McCollough
Journal:  Radiology       Date:  2012-10-22       Impact factor: 11.105

8.  Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220.

Authors:  Cynthia McCollough; Donovan M Bakalyar; Maryam Bostani; Samuel Brady; Kristen Boedeker; John M Boone; H Heather Chen-Mayer; Olav I Christianson; Shuai Leng; Baojun Li; Michael F McNitt-Gray; Roy A Nilsen; Mark P Supanich; Jia Wang
Journal:  AAPM Rep       Date:  2014-09

9.  Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.

Authors:  Jia Wang; Xinhui Duan; Jodie A Christner; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

10.  The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams.

Authors:  Maryam Khatonabadi; Hyun J Kim; Peiyun Lu; Kyle L McMillan; Chris H Cagnon; John J DeMarco; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

  10 in total
  4 in total

1.  CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY.

Authors:  Beatrice Steiniger; Chris Klippel; Ulf Teichgräber; Jürgen R Reichenbach; Martin Fiebich
Journal:  Radiat Prot Dosimetry       Date:  2022-05-13       Impact factor: 0.954

2.  Comparison of Application Value of Different Radiation Dose Evaluation Methods in Evaluating Radiation Dose of Adult Thoracic and Abdominal CT Scan.

Authors:  Jimin He; Guanwei Dong; Yi Deng; Jun He; ZhiGang Xiu; Fanzi Feng
Journal:  Front Surg       Date:  2022-03-25

3.  Real-time fully automated dosimetric computation for CT images in the clinical workflow: A feasibility study.

Authors:  Massimiliano Porzio; Choirul Anam
Journal:  Front Oncol       Date:  2022-08-11       Impact factor: 5.738

4.  Comparison of central, peripheral, and weighted size-specific dose in CT.

Authors:  Choirul Anam; Dwi Adhianto; Heri Sutanto; Kusworo Adi; Mohd Hanafi Ali; William Ian Duncombe Rae; Toshioh Fujibuchi; Geoff Dougherty
Journal:  J Xray Sci Technol       Date:  2020       Impact factor: 1.535

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.