Literature DB >> 30091590

Poly(3,4-ethylenedioxythiophene)-Poly(styrenesulfonate)-Coated Glassy-Carbon Electrode for Simultaneous Voltammetric Determination of Uranium and Plutonium in Fast-Breeder-Test-Reactor Fuel.

Rahul Agarwal1,2, Manoj K Sharma1,2, Kavitha Jayachandran1,2, Jayashree S Gamare2, Donald M Noronha2, Kaiprath V Lohithakshan2.   

Abstract

Uranium (U) and plutonium (Pu) contents in nuclear materials must be maintained to a definite level in order to get the desired performance of the fuel inside the reactor. Therefore, high accuracy and precision is an essential criterion for the determination of U and Pu. We already reported the voltammetric determination of Pu in the presence of U in fast-breeder-test-reactor (FBTR) fuel samples, but interfacial, coupled chemical reactions between U(IV) and Pu(IV) enhance the peak-current density of U(VI) reduction and thus make voltammetry unsuitable for the quantitative determination of U in the presence of Pu. Thus, developing a voltammetric method for the simultaneous determination of U and Pu is highly challenging. Herein, we report the simultaneous voltammetric determination of U and Pu in 1 M sulfuric acid (H2SO4) on a poly(3,4-ethylenedioxythiophene) (PEDOT)-poly(styrenesulfonate) (PSS)-modified glassy-carbon (GC) electrode (PEDOT-PSS/GC). The modified electrode shows enhanced performance compared with bare GC electrodes. The peak-current density for U(VI) reduction is enhanced in the presence of Pu(IV), but it attains saturation when [Pu]/[U] in solution is maintained ≥2. Hence, under these circumstances, the variation of Pu concentration no longer influences the U(VI)-reduction peak, and thus the quantitative determination of U in the presence of Pu is possible. No interference is observed from commonly encountered impurities present in FBTR fuel samples. This method shows accuracy and precision comparable to those of the biamperometry method. High robustness, fast analysis, simultaneous determination, reduced radiation exposure to the analyst, and ease of recovery of U and Pu from analytical waste makes it a suitable candidate to substitute the presently applied biamperometry method.

Entities:  

Year:  2018        PMID: 30091590     DOI: 10.1021/acs.analchem.8b00769

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Design and fabrication of a sensitive electrochemical sensor for uranyl ion monitoring in natural waters based on poly (brilliant cresyl blue).

Authors:  Zhiping Zhou; Yueming Zhou; Xizhen Liang; Jianqiang Luo; Shujuan Liu; Jianguo Ma
Journal:  Mikrochim Acta       Date:  2022-10-10       Impact factor: 6.408

2.  High effectiveness of pure polydopamine in extraction of uranium and plutonium from groundwater and seawater.

Authors:  Valery N Bliznyuk; Kamila Kołacińska; Alexander A Pud; Nikolay A Ogurtsov; Yuriy V Noskov; Brian A Powell; Timothy A DeVol
Journal:  RSC Adv       Date:  2019-09-24       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.