Literature DB >> 30091168

Comparison of the Fit of Lithium Disilicate Crowns made from Conventional, Digital, or Conventional/Digital Techniques.

Khaled Q Al Hamad1, Bashar A Al Rashdan2, Wael M Al Omari1, Nadim Z Baba3.   

Abstract

PURPOSE: To evaluate the fit of single crowns fabricated using conventional, digital, or cast digitization methods.
MATERIALS AND METHODS: One subject with a peg-shaped maxillary lateral incisor was selected in this study. Tooth preparation for an all-ceramic crown was performed and 10 conventional poly(vinyl siloxane) impressions, and 10 digital impressions using an intraoral scanner were made. Each working cast was scanned using a laboratory scanner and an intraoral scanner. Four groups were tested Group 1: conventional impressions. Group 2: cast laboratory scans. Group 3: cast scans using intraoral scanner. Group 4: direct intraoral scans. For group 1, heat-pressed glass ceramic crowns (IPS e.max Press) were fabricated using casts produced from the conventional impressions. For groups 2-4, crowns were milled using ceramic blocks (IPS e.max CAD). Ten crowns were fabricated for each group. Marginal and internal gaps were measured using a replica technique. Replicas were sectioned mesiodistally and buccolingually and were observed under a stereomicroscope. Three measurements were selected for each cut: occlusal, axial, and marginal. Statistical analysis was performed using two-way ANOVA and Tukey HSD tests.
RESULTS: For each replica, 6 measurements were made for the mesiodistal and the same for the buccolingual cuts, producing 12 measurement points per crown (4 measurements for marginal, 4 for axial, 4 for occlusal), 120 measurements for each group (40 measurements for marginal, 40 for axial, 40 for occlusal), and 480 measurements in total. Two-way ANOVA revealed location to be a significant factor (p = 0.001). No significant differences among groups (p = 0.456), and no interactions between groups and locations (p = 0.221) were found. Means for the occlusal site were significantly larger than other sites in most group combinations, while the difference between the marginal and axial sites was not significant. No significant differences among groups were found for each measurement. The marginal gaps ranged from 125.46 ± 25.39 μm for group 3 to 135.59 ± 24.07 μm for group 4. The smallest axial mean was in group 1 (98.10 ± 18.77 μm), and the largest was 127.25 ± 19.79 μm in group 4. The smallest occlusal mean was in group 2 (166.53 ± 36.51 μm), and the largest occlusal mean was in group 3 (203.32 ± 80.24 μm).
CONCLUSIONS: Ceramic crowns, which were made using all-digital approach or cast digitization by a laboratory or intraoral scanner had comparable fit to those produced by conventional approach.
© 2018 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD/CAM; ceramic; impression; intraoral scanner; laboratory; milling; replica; scanner

Mesh:

Substances:

Year:  2018        PMID: 30091168     DOI: 10.1111/jopr.12961

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Marginal and internal fit of feldspathic ceramic CAD/CAM crowns fabricated via different extraoral digitization methods: a micro-computed tomography analysis.

Authors:  Ece İrem Oğuz; Mehmet Ali Kılıçarslan; Mert Ocak; Burak Bilecenoğlu; Zeynep Ekici
Journal:  Odontology       Date:  2020-10-26       Impact factor: 2.634

2.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

3.  Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques.

Authors:  Jie Wu; Hongjun Xie; Alireza Sadr; Kwok-Hung Chung
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

4.  Comparative Evaluation of Adaptation of Esthetic Prefabricated Fiberglass and CAD/CAM Crowns for Primary Teeth: Microcomputed Tomography Analysis.

Authors:  Ece Irem Oguz; Tuğba Bezgin; Ayse Isıl Orhan; Kaan Orhan
Journal:  Biomed Res Int       Date:  2021-09-26       Impact factor: 3.411

Review 5.  Accuracy of marginal adaptation of posterior fixed dental prosthesis made from digital impression technique: A systematic review.

Authors:  Hanuman Chalapathi Kumar; Tannamala Pavan Kumar; Surapaneni Hemchand; Chinni Suneelkumar; Anirudhan Subha
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

6.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.