Literature DB >> 30077678

A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound.

Kiyoshi Hibi1, Ken Kozuma2, Shinjo Sonoda3, Tsutomu Endo4, Hiroyuki Tanaka5, Hiroyuki Kyono2, Ryoji Koshida6, Takayuki Ishihara7, Masaki Awata8, Teruyoshi Kume9, Kengo Tanabe10, Yoshihiro Morino11, Kengo Tsukahara12, Yuji Ikari13, Kenshi Fujii14, Masao Yamasaki15, Takeharu Yamanaka16, Kazuo Kimura17, Takaaki Isshiki18.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the utility of distal protection during percutaneous coronary intervention (PCI) in patients with acute coronary syndromes at high risk for distal embolization.
BACKGROUND: The results of previous clinical trials indicated that the routine use of distal protection in patients with ST-segment elevation myocardial infarction did not improve clinical outcomes. However, selective use of distal protection by means of a filter-based distal protection system has not been evaluated.
METHODS: Two hundred patients with acute coronary syndromes who had native coronary artery lesions and attenuated plaque with longitudinal length ≥5 mm on pre-PCI intravascular ultrasound were randomly assigned to undergo PCI with distal protection or conventional treatment.
RESULTS: The primary endpoint (no-reflow phenomenon) occurred in 26 patients (26.5%) in the distal protection group and 39 patients (41.7%) in the conventional treatment group (p = 0.026), and the corrected TIMI (Thrombolysis In Myocardial Infarction) frame count after revascularization was significantly lower in the distal protection group (23 vs. 30.5; p = 0.0003). The incidence of cardiac death, cardiac arrest, cardiogenic shock after revascularization requiring defibrillation, cardiopulmonary resuscitation, or extracorporeal membrane oxygenation was significantly lower in the distal protection group than in the conventional treatment group (0% vs. 5.2%; p = 0.028).
CONCLUSIONS: The use of distal embolic protection applied with a filter device decreased the incidence of the no-reflow phenomenon and was associated with fewer serious adverse cardiac events after revascularization than conventional PCI in patients with acute coronary syndromes with attenuated plaque ≥5 mm in length. (Assessment of Distal Protection Device in Patients at High Risk for Distal Embolism in Acute Coronary Syndrome [ACS] [VAMPIRE3]; NCT01460966).
Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acute coronary syndrome(s); distal embolism; distal protection device; intravascular ultrasound

Mesh:

Year:  2018        PMID: 30077678     DOI: 10.1016/j.jcin.2018.03.021

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  13 in total

1.  Prevention of distal embolization during directional coronary atherectomy.

Authors:  Hiroshi Ueda; Motoyoshi Maenaka; Kojiro Yoshimura; Yasunori Nishida
Journal:  J Cardiol Cases       Date:  2020-03-12

2.  The impact of the excimer laser on myocardial salvage in ST-elevation acute myocardial infarction via nuclear scintigraphy.

Authors:  Naoki Shibata; Kensuke Takagi; Itsuro Morishima; Naoki Yoshioka; Koichi Furui; Hiroaki Nagai; Yasunori Kanzaki; Ruka Yoshida; Yasuhiro Morita; Hideyuki Tsuboi; Toyoaki Murohara
Journal:  Int J Cardiovasc Imaging       Date:  2019-08-26       Impact factor: 2.357

3.  Balloon Deflation Strategy during Primary Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction: A Randomized Controlled Clinical Trial and Numerical Simulation-Based Analysis.

Authors:  Jun Gu; Yang Zhuo; Tian-Jiao Liu; Jie Li; Zhao-Fang Yin; Zuo-Jun Xu; Li Fan; Qing He; Kan Chen; Hua-Su Zeng; Xiao-Fei Wang; Yu-Qi Fan; Jun-Feng Zhang; Fu-You Liang; Chang-Qian Wang
Journal:  Cardiol Res Pract       Date:  2020-09-07       Impact factor: 1.866

4.  The Predictive Value of Baseline Target Lesion SYNTAX Score for No-Reflow during Urgent Percutaneous Coronary Intervention in Acute Myocardial Infarction.

Authors:  Guofeng Gao; Han Xu; Dong Zhang; Chenxi Song; Changdong Guan; Bo Xu; Dong Yin; Kefei Dou
Journal:  J Interv Cardiol       Date:  2021-08-04       Impact factor: 2.279

5.  Usefulness of excimer laser in acute coronary syndrome with left main coronary artery: a case series.

Authors:  Takuro Imaoka; Kensuke Takagi; Yasuhiro Morita; Yasunori Kanzaki; Hiroaki Nagai; Naoki Watanabe; Hideyuki Tsuboi; Itsuro Morishima
Journal:  Eur Heart J Case Rep       Date:  2020-12-01

Review 6.  Clinical expert consensus document on intravascular ultrasound from the Japanese Association of Cardiovascular Intervention and Therapeutics (2021).

Authors:  Yuichi Saito; Yoshio Kobayashi; Kenichi Fujii; Shinjo Sonoda; Kenichi Tsujita; Kiyoshi Hibi; Yoshihiro Morino; Hiroyuki Okura; Yuji Ikari; Junko Honye
Journal:  Cardiovasc Interv Ther       Date:  2021-11-12

Review 7.  A fresh look at coronary microembolization.

Authors:  Petra Kleinbongard; Gerd Heusch
Journal:  Nat Rev Cardiol       Date:  2021-11-16       Impact factor: 49.421

8.  Comparison of the incidence of periprocedural myocardial infarction between percutaneous coronary intervention with versus without rotational atherectomy using propensity score-matching.

Authors:  Yusuke Mizuno; Kenichi Sakakura; Hiroyuki Jinnouchi; Yousuke Taniguchi; Takunori Tsukui; Kei Yamamoto; Masaru Seguchi; Hiroshi Wada; Hideo Fujita
Journal:  Sci Rep       Date:  2021-05-27       Impact factor: 4.379

9.  Remote Ischemic Preconditioning for Percutaneous Coronary Intervention: Waiting for Godot?

Authors:  Allison B Hall; Emmanouil S Brilakis
Journal:  J Am Heart Assoc       Date:  2018-10-02       Impact factor: 5.501

10.  Factors associated with poor clinical outcomes of ST-elevation myocardial infarction in patients with door-to-balloon time <90 minutes.

Authors:  Takunori Tsukui; Kenichi Sakakura; Yousuke Taniguchi; Kei Yamamoto; Masaru Seguchi; Hiroyuki Jinnouchi; Hiroshi Wada; Hideo Fujita
Journal:  PLoS One       Date:  2020-10-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.