Literature DB >> 30073701

Semi-automated estimation of left ventricular ejection fraction by two-dimensional and three-dimensional echocardiography is feasible, time-efficient, and reproducible.

Katrine A Myhr1, Frederik H G Pedersen1, Charlotte B Kristensen1, Lasse Visby1, Christian Hassager1, Rasmus Mogelvang1.   

Abstract

PURPOSE: To compare two-dimensional (2D) and three-dimensional (3D) methods to estimate left ventricular ejection fraction (LVEF) with respect to feasibility, time consumption, and retest reproducibility.
METHODS: A total of 100 patients planned to undergo coronary artery bypass grafting and/or aortic valve replacement were included consecutively. 2D and 3D echocardiography was performed on all patients. Acquisition and analysis time as well as intra- and inter-examiner variability were assessed in 50 consecutive patients with 3 repeated echocardiographic examinations and analyses. LVEF was estimated by five different methods: uniplane, biplane, and single-beat triplane (SB3P), as well as semi-automated biplane (AutoEF) and 3D volumetric tracings (4D Auto LVQ). All methods were compared to Simpson's biplane method and feasibility was determined.
RESULTS: Feasibility of Simpson's uniplane method, Simpson's biplane method, AutoEF, SB3P, and 4D Auto LVQ was 97%, 92%, 86%, 70%, and 89%, respectively. All methods evaluated were 18%-33% faster (P < 0.001) than Simpson's biplane method (115 seconds, standard deviation 15 seconds). Compared to Simpson's biplane method mean LVEF was slightly underestimated by 4D Auto LVQ (-2 ± 8%, P = 0.02), but not significantly different when assessed by the other methods. AutoEF and 4D Auto LVQ showed the lowest test variability (intra-examiner coefficient of variation (CV) 10%-11%; inter-examiner CV 10%-12% vs intra-examiner CV 12%-18%; inter-examiner CV 12%-20%).
CONCLUSIONS: Estimation of LVEF by modern semi-automated 2D and 3D echocardiographic modalities is feasible, time-efficient, and reproducible.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac imaging; left ventricular ejection fraction; three-dimensional echocardiography

Mesh:

Year:  2018        PMID: 30073701     DOI: 10.1111/echo.14112

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Reliability and feasibility of automated function imaging for quantification in patients with left ventricular dilation: comparison with cardiac magnetic resonance.

Authors:  Yefen Chen; Wei Hua; Wenbo Yang; Zhongwei Shi; Yuehua Fang
Journal:  Int J Cardiovasc Imaging       Date:  2022-01-03       Impact factor: 2.357

2.  A new method to quantify left ventricular mass by 2D echocardiography.

Authors:  Charlotte Burup Kristensen; Katrine Aagaard Myhr; Frederik Fasth Grund; Niels Vejlstrup; Christian Hassager; Raj Mattu; Rasmus Mogelvang
Journal:  Sci Rep       Date:  2022-06-15       Impact factor: 4.996

  2 in total