Literature DB >> 30071267

Tap out: reducing waterborne Pseudomonas aeruginosa transmission in an intensive care unit.

M I Garvey1, M A C Wilkinson2, K L Holden2, T Martin2, J Parkes2, E Holden2.   

Abstract

BACKGROUND: Pseudomonas aeruginosa is a ubiquitous and important opportunistic pathogen in immunocompromised or critically ill patients. Nosocomial P. aeruginosa outbreaks have been associated with hospital water sources. AIM: To describe engineering interventions to minimize contamination of water outlets and the subsequent clinical impact.
METHODS: New tap outlets were fitted at selected outlets across the intensive care unit (ICU). Laboratory testing demonstrated that, following artificial contamination with P. aeruginosa, these taps could be effectively decontaminated using a thermal washer-disinfector. Water samples were collected weekly from new outlets on the ICU over an eight-month period and tested for the enumeration of P. aeruginosa via membrane filtration. Surveillance of P. aeruginosa from clinical specimens was routinely undertaken.
FINDINGS: Prior to the interventions, water sampling on ICU indicated that 30% of the outlets were positive for P. aeruginosa at any one time, and whole genome sequencing data suggested at least 30% transmission from water to patient. Since their installation, weekly sampling of the new tap outlets has been negative for P. aeruginosa, and the number of P. aeruginosa clinical isolates has fallen by 50%.
CONCLUSION: Installation and maintenance of tap outlets free of P. aeruginosa can substantially reduce the number of P. aeruginosa clinical isolates in an ICU.
Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Infection control; Intensive care unit; Pseudomonas aeruginosa; Tap outlets; Water testing frequency; Waterborne transmission

Mesh:

Year:  2018        PMID: 30071267     DOI: 10.1016/j.jhin.2018.07.039

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  3 in total

1.  Infection prevention requirements for the medical care of immunosuppressed patients: recommendations of the Commission for Hospital Hygiene and Infection Prevention (KRINKO) at the Robert Koch Institute.

Authors: 
Journal:  GMS Hyg Infect Control       Date:  2022-04-13

2. 

Authors: 
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2021-02       Impact factor: 1.513

3.  Decontamination effect of neutral electrolysed water for spray nozzles of electric warm-water bidet toilet seats in the healthcare setting.

Authors:  Aiko Itami; Satoshi Hori; Shigeki Misawa
Journal:  Infect Prev Pract       Date:  2021-04-22
  3 in total