Literature DB >> 30067490

Complications of Radiofrequency Catheter Ablation: Can We Prevent Steam Pops?

Juan F Viles-Gonzalez1, Enrique Berjano2, Andre d'Avila3.   

Abstract

Keywords:  ablation; biophysics; complication; impedance; intracardiac echocardiography; steam pop

Mesh:

Substances:

Year:  2017        PMID: 30067490     DOI: 10.1016/j.jacep.2017.11.003

Source DB:  PubMed          Journal:  JACC Clin Electrophysiol        ISSN: 2405-500X


× No keyword cloud information.
  6 in total

1.  Steam pop during cavo-tricuspid isthmus ablation shown by intracardiac echocardiography.

Authors:  Amato Santoro; Andrea Romano; Filippo Lamberti
Journal:  J Cardiol Cases       Date:  2020-09-14

2.  Spatial temperature reconstructions in myocardial tissues undergoing radiofrequency ablations by performing high-resolved temperature measurements.

Authors:  Martina Zaltieri; Pietro Rossi; Stefano Bianchi; Marco Polselli; Marta Niscola; Veronica Fanti; Carlo Massaroni; Emiliano Schena; Filippo Maria Cauti
Journal:  J Interv Card Electrophysiol       Date:  2022-02-17       Impact factor: 1.900

3.  Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation.

Authors:  Nian Liu; Qianqian Zhao; Linling Li; Mengxia Zhang; Jiao Huang; Sheng Wei; Songnan Wen; Yanfei Ruan; Xueyuan Guo; Songnan Li; Chengxi Jiang; Ribo Tang; Caihua Sang; Deyong Long; Ronghui Yu; Rong Bai; Xin Du; Jianzeng Dong; Changsheng Ma
Journal:  J Interv Card Electrophysiol       Date:  2019-02-02       Impact factor: 1.900

4.  Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation.

Authors:  Jianfeng Luo; Fei Guo; Hongjun Zhu; Hao Su; Yuanbo Wu; Jing Zhu; Can Zhang; Jian Xu
Journal:  Front Physiol       Date:  2022-01-25       Impact factor: 4.566

5.  Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial.

Authors:  Moloy Das; Armin Luik; Ewen Shepherd; Matthew Sulkin; Jacob Laughner; Tobias Oesterlein; Elizabeth Duffy; Christian Meyer; Pierre Jais; Josselin Duchateau; Arthur Yue; Waqas Ullah; Pablo Ramos; Ignacio García-Bolao
Journal:  Europace       Date:  2021-07-18       Impact factor: 5.214

6.  Simple periprocedural precautions to reduce Doppler microembolic signals during AF ablation.

Authors:  Marian Christoph; David Poitz; Silvio Quick; Carsten Wunderlich; Christian Pfluecke; Mathias Forkmann; Yan Huo; Thomas Gaspar; Steffen Schoen; Karim Ibrahim
Journal:  J Interv Card Electrophysiol       Date:  2021-05-31       Impact factor: 1.759