Electrochemical Glucose Sensors Enhanced by Methyl Viologen and Vertically Aligned Carbon Nanotube Channels.

Benjamin J Brownlee, Meisam Bahari, John N Harb, Jonathan C Claussen1, Brian D Iverson.   

Abstract

Freestanding, vertically aligned carbon nanotubes (VACNTs) were patterned into 16 μm diameter microchannel arrays for flow-through electrochemical glucose sensing. Non-enzymatic sensing of glucose was achieved by the chemical reaction of glucose with methyl viologen (MV) at an elevated temperature and pH (0.1 M NaOH), followed by the electrochemical reaction of reduced-MV with the VACNT surface. The MV sensor required no functionalization (including no metal) and was able to produce on average 3.4 electrons per glucose molecule. The current density of the MV sensor was linear with both flow rate and glucose concentration. Challenges with interference chemicals were mitigated by operating at a low potential of -0.2 V vs Ag/AgCl. As a comparison, enzymatic VACNT sensors with platinum nano-urchins were functionalized with glucose oxidase by covalent binding (1-ethyl-3-(-3-dimethylaminopropyl)carbodiimide/ N-hydroxysuccinimide) or by polymer entrapment [poly(3,4-ethylene-dioxythiophene)] and operated in phosphate buffered saline. With normalization by the overall cross-sectional area of the flow (0.713 cm2), the sensitivity of the MV, enzyme-in-solution, and covalent sensors were 45.93, 18.77, and 1.815 mA cm-2 mM-1, respectively. Corresponding limits of detection were 100, 194, and 311 nM glucose. The linear sensing ranges for the sensors were 250 nM to 200 μM glucose for the MV sensor, 500 nM to 200 μM glucose for the enzyme-in-solution sensor, and 1 μM to 6 mM glucose for the covalent sensor. The flow cell and sensor cross-sectional area were scaled down (0.020 cm2) to enable detection from 200 μL of glucose with MV by flow injection analysis. The sensitivity of the small MV sensor was 5.002 mA cm-2 mM-1, with a limit of detection of 360 nM glucose and a linear range up to at least 150 μM glucose. The small MV sensor has the potential to measure glucose levels found in 200 μL of saliva.

Entities:  

Keywords:  electrochemical sensor; flow injection analysis (FIA); glucose; methyl viologen; microchannel; vertically aligned carbon nanotubes (VACNTs)

Mesh:

Substances:

Year:  2018        PMID: 30067019     DOI: 10.1021/acsami.8b08997

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  4 in total

1.  Developing an integrated microfluidic and miniaturized electrochemical biosensor for point of care determination of glucose in human plasma samples.

Authors:  Shamim Azimi; Ali Farahani; Aristides Docoslis; Sahar Vahdatifar
Journal:  Anal Bioanal Chem       Date:  2021-01-02       Impact factor: 4.142

Review 2.  Vertically Aligned Carbon Nanotubes as a Unique Material for Biomedical Applications.

Authors:  August Kohls; Mackenzie Maurer Ditty; Fahimeh Dehghandehnavi; Si-Yang Zheng
Journal:  ACS Appl Mater Interfaces       Date:  2022-01-28       Impact factor: 10.383

Review 3.  Water soluble organic electrochromic materials.

Authors:  Thomas A Welsh; Emily R Draper
Journal:  RSC Adv       Date:  2021-01-27       Impact factor: 3.361

4.  The Construct CoSe2 on Carbon Nanosheets as High Sensitivity Catalysts for Electro-Catalytic Oxidation of Glucose.

Authors:  Di Wang; Ying Chang
Journal:  Nanomaterials (Basel)       Date:  2022-02-07       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.