Jae Gun Kwak1, Sungkyu Cho2, Woong-Han Kim3. 1. Department of Thoracic and Cardiovascular Surgery, Seoul National University Children's Hospital, Seoul, Republic of Korea. 2. Department of Thoracic and Cardiovascular Surgery, Sejong General Hospital, Bucheon, Republic of Korea. 3. Department of Thoracic and Cardiovascular Surgery, Seoul National University Children's Hospital, Seoul, Republic of Korea. Electronic address: woonghan@snu.ac.kr.
Abstract
BACKGROUND: Open surgical implantation of epicardial leads in neonates and infants remains the first option of treatment. We reviewed the long-term outcomes after epicardial pacemaker implantation in neonates and infants. METHODS: From 1989 to 2016, 48 patients (16 neonates) underwent pacemaker implantation within the first year of life. Their median age and weight were 66.5days (range: 0∼319 days), and 4.2kg (range: 1.9∼9.3kg), respectively, at the time of first pacemaker implantation. The indications for pacemaker implantation were postoperative or congenital atrioventricular block, sinus node dysfunction, and/or myocarditis-induced atrioventricular block. Forty-six (46) unipolar epicardial leads (non-steroid-eluting: 22; steroid-eluting: 24) and two bipolar leads (steroid-eluting) were inserted using a median sternotomy or subxiphoid approach. RESULTS: The mean follow-up duration was 8.5±7.9years. The most commonly used generator mode at first implantation was VVI (n=24, 50.0%). Eleven (11) generator mode changes from the initial VVI or VVIR to dual-chamber pacing were made at a mean of 7.0±6.2years after the first implantation for better inter-chamber synchrony and ventricular function. Freedom from reoperation for generator change after the first implantation was 95.3, 70.6, and 21.9% at 1, 5, and 10 years. Eighteen (18) lead malfunction events (34.1%) were detected. Freedom from reoperation for lead change was 97.8, 76.2, and 46.3% at 1, 5, and 10 years. The lead replacement rate was significantly higher in patients with non-steroid-eluting than steroid-eluting leads (p=0.045). CONCLUSIONS: Neonates and infants require more frequent changes in pacemaker generator and leads than the older population. The use of steroid-eluting leads increased lead longevity and reduced the need for surgical re-interventions.
BACKGROUND: Open surgical implantation of epicardial leads in neonates and infants remains the first option of treatment. We reviewed the long-term outcomes after epicardial pacemaker implantation in neonates and infants. METHODS: From 1989 to 2016, 48 patients (16 neonates) underwent pacemaker implantation within the first year of life. Their median age and weight were 66.5days (range: 0∼319 days), and 4.2kg (range: 1.9∼9.3kg), respectively, at the time of first pacemaker implantation. The indications for pacemaker implantation were postoperative or congenital atrioventricular block, sinus node dysfunction, and/or myocarditis-induced atrioventricular block. Forty-six (46) unipolar epicardial leads (non-steroid-eluting: 22; steroid-eluting: 24) and two bipolar leads (steroid-eluting) were inserted using a median sternotomy or subxiphoid approach. RESULTS: The mean follow-up duration was 8.5±7.9years. The most commonly used generator mode at first implantation was VVI (n=24, 50.0%). Eleven (11) generator mode changes from the initial VVI or VVIR to dual-chamber pacing were made at a mean of 7.0±6.2years after the first implantation for better inter-chamber synchrony and ventricular function. Freedom from reoperation for generator change after the first implantation was 95.3, 70.6, and 21.9% at 1, 5, and 10 years. Eighteen (18) lead malfunction events (34.1%) were detected. Freedom from reoperation for lead change was 97.8, 76.2, and 46.3% at 1, 5, and 10 years. The lead replacement rate was significantly higher in patients with non-steroid-eluting than steroid-eluting leads (p=0.045). CONCLUSIONS: Neonates and infants require more frequent changes in pacemaker generator and leads than the older population. The use of steroid-eluting leads increased lead longevity and reduced the need for surgical re-interventions.