Literature DB >> 30063305

Clinical Evaluation of Sonic-Activated High Viscosity Bulk-Fill Nanohybrid Resin Composite Restorations in Class II Cavities: A Prospective Clinical Study up to 2 Years.

T T Akalιn1, F O Bozkurt1, M Kusdemir1, A Özsoy1, M Özcan2.   

Abstract

This study evaluated the clinical performance of a bulk-fill resin composite in class II cavities for up to 2 years. Class II restorations (N=111) were made using a nanohybrid bulk-fill resin composite (SonicFill, Kerr Corp.) and evaluated following 1 week after placement, at 6 months, and thereafter annually up to 2 years using the United States Public Health Service (USPHS) criteria. The changes were analyzed using the McNemar test and the Kaplan-Meier method. No secondary caries was observed until the final recall. One restoration underwent endodontic treatment after 2 months following the restorative procedure and was deemed a failure. The overall success rate was 99.1%. Colour match deteriorated from a score of 0 to 1 in eight restorations from baseline to 6 months and six restorations showed marginal staining at final recall. Bulk-fill resin composite (SonicFill) showed acceptable clinical performance through 2 years of service but colour match to the tooth started to show some deterioration within the first 6 months. Copyright
© 2018 Dennis Barber Ltd.

Keywords:  Adhesion; Bulk-Fill Composite; Class I and II Restorations; Clinical Study; Resin Composite; SonicFill; USPHS

Mesh:

Substances:

Year:  2018        PMID: 30063305     DOI: 10.1922/EJPRD_01620Akalin09

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  1 in total

1.  One-year clinical evaluation of bulk-fill composite resin restorations plasticized by preheating and ultrasonics: A randomized clinical trial.

Authors:  Girija S Sajjan; Gnana Sindhu Dutta; K Madhu Varma; R Kalyan Satish; Anil Kumar Pulidindi; Vishal Babu Kolla
Journal:  J Conserv Dent       Date:  2022-05-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.