Literature DB >> 30061064

Modal frequency and shape curvature as a measure of implant fixation: A computer study on the acetabular cup.

Petr Henyš1, Steven Leuridan2, Quentin Goossens2, Michiel Mulier2, Leonard Pastrav2, Wim Desmet2, Jos Vander Sloten2, Kathleen Denis2, Lukáš Čapek3.   

Abstract

Modal parameters are often investigated in order to assess the initial fixation of an implant. Most of studies are focused on the natural frequencies and frequency response function. Usually the femoral stem is tested although the acetabular cup fixation is important as well. The results of implant stability assessment are inconsistent and seem to suggest that frequency as a stability indicator is not sufficiently sensitive. In this study the sensitivity of the modal properties to changes in the bone-implant interface was investigated with the help of the finite element method (FEM). A novel fixation index based on modal shape curvature was investigated as a potential measure of the implant fixation. Modal frequencies are sensitive to interface changes in some manner, but suffer from insensitivity to local changes at bone-implant interface. The sensitivity up to 44% of natural frequencies to stiffness change due insertion steps was observed. The tested damage indicators are able to detect localized small changes in peripheral stiffness (5% stiffness reduction) with 95% confidence under the noise up to 1%. The modal shapes and their curvatures have a great potential to be a robust fixation indicator.
Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

Keywords:  Acetabular cup; Damage index; Finite element method; Initial fixation; Modal shapes

Mesh:

Year:  2018        PMID: 30061064     DOI: 10.1016/j.medengphy.2018.07.003

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Experimental validation of adaptive pedicle screws-a novel implant concept using shape memory alloys.

Authors:  Michael Werner; Niels Hammer; Christian Rotsch; Isabell Berthold; Mario Leimert
Journal:  Med Biol Eng Comput       Date:  2019-11-18       Impact factor: 2.602

2.  Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw.

Authors:  Mohammadjavad Einafshar; Ata Hashemi; Gerrit Harry van Lenthe
Journal:  Arch Bone Jt Surg       Date:  2022-02

3.  Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery.

Authors:  Shunsuke Kikuchi; Katsuhiro Mikami; Daisuke Nakashima; Toshiyuki Kitamura; Noboru Hasegawa; Masaharu Nishikino; Arihiko Kanaji; Masaya Nakamura; Takeo Nagura
Journal:  Sensors (Basel)       Date:  2019-11-08       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.