Literature DB >> 30060888

Contrast-enhanced and unenhanced diffusion-weighted imaging of the breast at 3 T.

M Fanariotis1, I Tsougos2, M Vlychou3, I Fezoulidis3, K Vassiou3.   

Abstract

AIM: To evaluate the effect of intravenous gadolinium contrast agent on diffusion-weighted sequences and apparent diffusion coefficient (ADC) measurements at 3 T.
MATERIALS AND METHODS: Sixty-two biopsy-proven breast lesions were included in this prospective study. Magnetic resonance imaging (MRI) was performed at 3 T, using four echo-planar diffusion-weighted sequences (7,100 ms repetition time, 84 ms echo time) with b-values of 0 and 850, and 0 and 1,000 s/mm2. The first pair of DWI sequences was taken before intravenous contrast medium injection. The second pair of sequences was taken 6.5 minutes after intravenous contrast medium administration (right after the dynamic T1 sequence). A freeform region of interest (ROI) was drawn inside the lesion excluding adjacent normal tissue, necrotic, or cystic components and ADC values were calculated. The paired samples t-test was used to assess differences between ADC measurements before and after intravenous contrast medium administration. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were calculated for each diffusion sequence.
RESULTS: Twenty-seven malignant and 35 benign lesions were analysed. Fifty-eight lesions were masses, and four lesions were non-mass-like enhancements (NMLEs). Two of the NMLEs were malignant, and two were benign lesions. The contrast-enhanced ADC measurements were lower than the unenhanced measurements on b=850 and 1,000 s/mm2 (p<0.05). The receiver operating characteristic (ROC) analysis displayed similar area under the curve values between the different diffusion sequences.
CONCLUSION: The injection of intravenous contrast medium reduces ADC values; however, the effect of contrast medium is modest. Sensitivity and specificity are not significantly affected.
Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30060888     DOI: 10.1016/j.crad.2018.06.019

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Performance of abbreviated protocols versus unenhanced MRI in detecting occult breast lesions of mammography in patients with dense breasts.

Authors:  Peipei Chen; Guangrui Shao; Baijie Li; Huikun Zhang; Juan Xiao; Suhong Zhao
Journal:  Sci Rep       Date:  2022-08-11       Impact factor: 4.996

2.  Multidimensional Diffusion Magnetic Resonance Imaging for Characterization of Tissue Microstructure in Breast Cancer Patients: A Prospective Pilot Study.

Authors:  Isaac Daimiel Naranjo; Alexis Reymbaut; Patrik Brynolfsson; Roberto Lo Gullo; Karin Bryskhe; Daniel Topgaard; Dilip D Giri; Jeffrey S Reiner; Sunitha B Thakur; Katja Pinker-Domenig
Journal:  Cancers (Basel)       Date:  2021-03-31       Impact factor: 6.639

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.