Application of carbon sensors for potentiometric determination of copper(II) in water and biological fluids of Wilson disease patients. Studying the surface reaction using SEM, EDX, IR and DFT.

Eman Yossri Frag1, Marwa El Badry Mohamed2, Elham M Fahim2.   

Abstract

The performance characteristics of a new selective and sensitive modified screen printed electrode (MSPE; electrode I) and carbon paste electrode (MCPE; electrode II) based on 2-N, N-dimethylcarbamimidoyl (metformin) as modifier for the potentiometric determination of copper (II) in water sample, serum and urine samples of Wilson disease patients have been optimized. The chemical reaction which happens between Cu (II) and the modifier on the surface of the sensors was investigated with scanning electron microscope (SEM), energy dispersive X-ray analysis (EDX), IR spectra measurement and computational calculations at DFT/B3LYP. The sensors showed perfect potentiometric response for Cu (II) over concentration range of 1.0 × 10-6 - 1.0 × 10-2 and 1.0 × 10-6 - 5.0 × 10-2 mol L-1 with a detection limit of 1.0 × 10-6 mol L-1with divalent slope value 30.2 and 31.8 mV decade-1 over the pH range of 2-6 for MCPE and MSPE, respectively. MSPE was stable with repeatable potential over period of 37 days and exhibits fast response time of 6 and 10 s for MSPE and MCPE, respectively. Also, these sensors exhibited good selectivity towards Cu(II) with respect to other metal ions and have higher antibacterial activity against Staphylococcus aureus as Gram-positive bacteria and Escherichia coli as Gram-negative bacteria. The obtained results using the sensors were in agreement with those obtained using the reported method.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Copper; Ion selective electrodes; Metformin; Potentiometric determination; Tricresylphosphate; Wilson disease

Mesh:

Substances:

Year:  2018        PMID: 30059866     DOI: 10.1016/j.bios.2018.07.024

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Colorimetric determination of copper(II) by using branched-polyethylenimine droplet evaporation on a superhydrophilic-superhydrophobic micropatterned surface.

Authors:  Hong Shao; Xiaokun Wen; Yadan Ding; Xia Hong; Huiying Zhao
Journal:  Mikrochim Acta       Date:  2019-10-16       Impact factor: 5.833

2.  Potentiometric Sensor Based on Carbon Paste Electrode for Monitoring Total Residual Chlorine in Electrolytically-Treated Ballast Water.

Authors:  Yaning Zhang; Zhihui Li; Xiaotong Guo; Guangzhou Liu; Shuyong Zhang
Journal:  Sensors (Basel)       Date:  2021-01-07       Impact factor: 3.576

3.  A comparative study on selectivity and sensitivity of new chromium and copper electrodes.

Authors:  Elnaz Bakhshi Sarabi; Leila Hajiaghababaei; Mohammad Reza Allahgholi Ghasri; Seyed Enayatollah Mottaghinejad; Ali Parsa
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.