Failure load and stress analysis of orthodontic miniscrews with different transmucosal collar diameter.

Maria Francesca Sfondrini1, Paola Gandini1, Roberto Alcozer1, Pekka K Vallittu2, Andrea Scribante3.   

Abstract

Miniscrews have been introduced in orthodontics as temporary anchorage devices (TADs), in order to move the correct teeth and avoid other elements to slide toward a wrong direction. Moreover the ease of use of TADs encouraged clinicians to use miniscrews also for non-conventional purposes, as fixation in mandibular fracture, mini-implant supported temporary pontics, miniscrew-assisted rapid palatal expanders and distalizers. These applications develop higher forces, so TAD fracture can be an unwanted complication. Some authors analyzed torsional loads but no studies measured forces required to bend the screws and ultimate flexural strength. Accordingly, in the present report, Ti-6Al-4V TADs were mechanically evaluated. Seven different diameters of screws were tested: 1.3 mm (Aarhus Screw, Medicon), 1.5 mm (Spider Screw, HDC), 1.6 mm (Aarhus Screw, Medicon), 1.7 mm (Ortho Easy, Forestadent), 1.8 mm (Ortho Implant, 3 M), 1.9 mm (Spider Screw, HDC) and 2.0 mm (Storm, Kristal). The forces to bend the titanium TADs were measured at 0.1 mm, 0.2 mm magnitude of deflections and at maximum load (as peak before screw fracture) in air with a universal testing machine. Statistical analyses were performed. Both at 0.1 mm and at 0.2 mm deflections and at maximum load, the significantly highest forces were reported with 1.7, 1.8, 1.9, and 2.0 mm TADs. The lowest values were reported with 1.6, 1.5, and 1.3 mm mini-implants. No significant differences were reported between 1.6 mm and 1.7 mm screws. It was found that load values in N versus stress in MPa were not fully comparable when screws with small and larger diameter were compared. Therefore, when placing a miniscrew for applications that need maximum shear bending resistance, these results would be considered in order to reduce risk of unwanted fracture.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anchorage; Bend; Dentistry; Implant; Load; Miniscrew; Orthodontics; Shear; TAD; Temporary anchorage device

Mesh:

Substances:

Year:  2018        PMID: 30059839     DOI: 10.1016/j.jmbbm.2018.07.032

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  13 in total

1.  Effects of Recent/Healed Post-Extraction Protocols on Incisor and Canine Alignment During Fixed Orthodontic Appliance Therapy.

Authors:  Adedayo Ayomide Olabintan; Olayinka Donald Otuyemi; Kikelomo Adebanke Kolawole
Journal:  Turk J Orthod       Date:  2022-06

2.  Multifunctional Templates for Minimized Osteotomy, Implantation, and Palatal Distraction with a Mini-Screw-Assisted Expander in Schizodontism and Maxillary Deficit.

Authors:  Manfred Nilius; Katrin Hess; Dominik Haim; Bernhard Weiland; Guenter Lauer
Journal:  Case Rep Dent       Date:  2020-09-09

3.  Minimally Invasive Diastema Restoration with Prefabricated Sectional Veneers.

Authors:  Claudio Novelli; Andrea Scribante
Journal:  Dent J (Basel)       Date:  2020-06-24

4.  Seven-year follow-up of the nonsurgical expansion of maxillary and mandibular arches in a young adult: A case report.

Authors:  Ting-Ting Yu; Jing Li; Da-Wei Liu
Journal:  World J Clin Cases       Date:  2020-11-06       Impact factor: 1.337

Review 5.  Essential Attributes of Clear Aligner Therapy in terms of Appliance Configuration, Hygiene, and Pain Levels during the Pandemic: A Brief Review.

Authors:  Anand Marya; Adith Venugopal; Nikhilesh Vaid; Mohammad Khursheed Alam; Mohmed Isaqali Karobari
Journal:  Pain Res Manag       Date:  2020-12-08       Impact factor: 3.037

6.  Analysis of Root Canal Curvature and Root Canal Morphology of Maxillary Posterior Teeth in Guizhou, China.

Authors:  Xin Qiao; Tingting Xu; Liang Chen; Deqin Yang
Journal:  Med Sci Monit       Date:  2021-01-13

7.  Optimal Implantation Site of Orthodontic Micro-Screws in the Mandibular Anterior Region Based on CBCT.

Authors:  Yannan Wang; Quan Shi; Feng Wang
Journal:  Front Physiol       Date:  2021-05-20       Impact factor: 4.566

8.  Clinical effectiveness of orthodontic miniscrew implantation guided by a novel cone beam CT image-based computer aided design and computer aided manufacturing (CAD-CAM) template.

Authors:  Lingling Qiu; Hui Xu; Pingping Feng; Xiaoyan Sha; Hongwei Zhang
Journal:  Ann Transl Med       Date:  2021-06

9.  Evaluation of the Relationship Between Maxillary Sinus Wall and Maxillary Canines and Posterior Teeth Using Cone-Beam Computed Tomography.

Authors:  Yifei Qin; Guang Shu; Tianmin Xu
Journal:  Med Sci Monit       Date:  2020-09-24

10.  Management of a Complex Dentoalveolar Traumatic Injury with Multiple Avulsions.

Authors:  Anita Thakur; Seema Thakur
Journal:  Case Rep Dent       Date:  2021-06-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.