Literature DB >> 30058765

A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non-dominant wrist.

Duncan S Buchan1, Fiona McSeveney1, Gillian McLellan1.   

Abstract

The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non-dominant wrist. Fifty-five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously for 1 day, one on their non-dominant wrist and the other on their dominant wrist. Paired t-tests were undertaken with sequential Holm-Bonferroni corrections to compare wear time, moderate-vigorous physical activity (MVPA), time spent in 10-min bouts of MVPA (MVPA10 min ) and the average magnitude of dynamic wrist acceleration (ENMO). Level of agreement between outcome variables from the wrists was examined using intraclass correlation coefficients (ICC, single measures, absolute agreement) with 95% confidence intervals and limits of agreement (LoA). Time spent across acceleration levels in 40 mg resolution were also examined. There were no significant differences between the non-dominant and dominant wrist for ENMO, wear time, MVPA or MVPA10 min . Agreement between wrists was strong for most outcomes (ICC ≥0·92) including wear time, ENMO, MVPA, MVPA10 min and the distribution of time across acceleration levels. Agreement was strong in the low acceleration bands (ICC = 0·970 and 0·922) with a mean bias of 3·08 min (LoA -55·18 to 61·34) and -5·43 (LoA -43·47 to 32·62). In summary, ENMO, MVPA, MVPA10 min , wear time and the distribution of time across acceleration levels compared well at the group level. The LOA from the two lowest acceleration levels suggest further work over a longer monitoring period is needed to determine whether outputs from each wrist are comparable.
© 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

Keywords:  zzm321990GGIRzzm321990; Euclidean Norm Minus One; adults; agreement; moderate-vigorous physical activity; wrist-worn

Mesh:

Year:  2018        PMID: 30058765     DOI: 10.1111/cpf.12538

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  8 in total

1.  The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings.

Authors:  Sunku Kwon; Neng Wan; Ryan D Burns; Timothy A Brusseau; Youngwon Kim; Santosh Kumar; Emre Ertin; David W Wetter; Cho Y Lam; Ming Wen; Wonwoo Byun
Journal:  Sensors (Basel)       Date:  2021-02-18       Impact factor: 3.576

2.  On Placement, Location and Orientation of Wrist-Worn Tri-Axial Accelerometers during Free-Living Measurements.

Authors:  Marcin Straczkiewicz; Nancy W Glynn; Jaroslaw Harezlak
Journal:  Sensors (Basel)       Date:  2019-05-06       Impact factor: 3.576

3.  What gait features influence the amount and intensity of physical activity in people with multiple sclerosis?

Authors:  Massimiliano Pau; Micaela Porta; Giancarlo Coghe; Eleonora Cocco
Journal:  Medicine (Baltimore)       Date:  2021-03-05       Impact factor: 1.817

4.  Does Multiple Sclerosis Differently Impact Physical Activity in Women and Man? A Quantitative Study Based on Wearable Accelerometers.

Authors:  Massimiliano Pau; Micaela Porta; Giancarlo Coghe; Jessica Frau; Lorena Lorefice; Eleonora Cocco
Journal:  Int J Environ Res Public Health       Date:  2020-11-28       Impact factor: 3.390

5.  Investigating Wrist-Based Acceleration Summary Measures across Different Sample Rates towards 24-Hour Physical Activity and Sleep Profile Assessment.

Authors:  Athanasios Tsanas
Journal:  Sensors (Basel)       Date:  2022-08-17       Impact factor: 3.847

6.  RELATIONSHIP BETWEEN PHYSICAL ACTIVITY PARTICIPATION AND RECOVERY OUTCOMES IN COLLEGE-AGED ADULTS WITH A CONCUSSION.

Authors:  Kyle M Petit; Christopher Kuenze; Karin A Pfeiffer; Nathan Fitton; Mathew Saffarian; Tracey Covassin
Journal:  J Athl Train       Date:  2021-07-30       Impact factor: 3.824

7.  Evaluating the performance of raw and epoch non-wear algorithms using multiple accelerometers and electrocardiogram recordings.

Authors:  Shaheen Syed; Bente Morseth; Laila A Hopstock; Alexander Horsch
Journal:  Sci Rep       Date:  2020-04-03       Impact factor: 4.379

8.  Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adults.

Authors:  Jairo H Migueles; Cristina Cadenas-Sanchez; Alex V Rowlands; Pontus Henriksson; Eric J Shiroma; Francisco M Acosta; Maria Rodriguez-Ayllon; Irene Esteban-Cornejo; Abel Plaza-Florido; Jose J Gil-Cosano; Ulf Ekelund; Vincent T van Hees; Francisco B Ortega
Journal:  Sci Rep       Date:  2019-12-03       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.