Literature DB >> 30047223

Closed-loop driven by control-to-range algorithm outperforms threshold-low-glucose-suspend insulin delivery on glucose control albeit not on nocturnal hypoglycaemia in prepubertal patients with type 1 diabetes in a supervised hotel setting.

Eric Renard1,2,3, Nadia Tubiana-Rufi4, Elisabeth Bonnemaison-Gilbert5, Régis Coutant6, Fabienne Dalla-Vale7, Anne Farret1,3, Amélie Poidvin4, Natacha Bouhours-Nouet6, Charlotte Abettan1,3, Caroline Storey-London4, Aurelie Donzeau6, Jerome Place1,3, Marc D Breton8.   

Abstract

This randomized control trial investigated glucose control with closed-loop (CL) versus threshold-low-glucose-suspend (TLGS) insulin pump delivery in pre-pubertal children with type 1 diabetes in supervised hotel conditions. The patients [n = 24, age range: 7-12, HbA1c: 7.5 ± 0.5% (58 ± 5 mmol/mol)] and their parents were admitted twice at a 3-week interval. CL control to range or TLGS set at 3.9 mmoL/L were assessed for 48 hour in randomized order. Admissions included three meals and one snack, and physical exercise. Meal boluses followed individual insulin/carb ratios. While overnight (22:00-08:00) per cent continuous glucose monitoring (CGM) time below 3.9 mmol/L (primary outcome) was similar, time in ranges 3.9 to 10.0 and 3.9 to 7.8 mmoL/L and mean CGM were all significantly improved with CL (P < 0.001). These results were confirmed over the whole 48 hour. Disconnections between devices and limited accuracy of glucose sensors in the hypoglycaemic range appeared as limiting factors for optimal control. CL mode was well accepted while fear of hypoglycaemia was unchanged. CL did not minimize nocturnal hypoglycaemia exposure but improved time in target range compared to TLGS. Although safe and well-accepted, CL systems would benefit from more integrated devices.
© 2018 John Wiley & Sons Ltd.

Entities:  

Keywords:  CSII; clinical trial; continuous glucose monitoring (CGM); glycaemic control; hypoglycaemia; type 1 diabetes

Mesh:

Substances:

Year:  2018        PMID: 30047223     DOI: 10.1111/dom.13482

Source DB:  PubMed          Journal:  Diabetes Obes Metab        ISSN: 1462-8902            Impact factor:   6.577


  3 in total

1.  Closed loop control in adolescents and children during winter sports: Use of the Tandem Control-IQ AP system.

Authors:  Laya Ekhlaspour; Gregory P Forlenza; Daniel Chernavvsky; David M Maahs; R Paul Wadwa; Mark D Deboer; Laurel H Messer; Marissa Town; Jennifer Pinnata; Geoff Kruse; Boris P Kovatchev; Bruce A Buckingham; Marc D Breton
Journal:  Pediatr Diabetes       Date:  2019-05-23       Impact factor: 4.866

2.  Technological Ecological Momentary Assessment Tools to Study Type 1 Diabetes in Youth: Viewpoint of Methodologies.

Authors:  Mary Katherine Ray; Alana McMichael; Maria Rivera-Santana; Jacob Noel; Tamara Hershey
Journal:  JMIR Diabetes       Date:  2021-06-03

3.  In vivo investigation of the tissue response to commercial Teflon insulin infusion sets in large swine for 14 days: the effect of angle of insertion on tissue histology and insulin spread within the subcutaneous tissue.

Authors:  Gabriella Eisler; Jasmin R Kastner; Marc C Torjman; Abdurizzagh Khalf; David Diaz; Alek R Dinesen; Channy Loeum; Mathew L Thakur; Paul Strasma; Jeffrey I Joseph
Journal:  BMJ Open Diabetes Res Care       Date:  2019-12-08
  3 in total