Literature DB >> 30041140

Mechanical properties and electrochemical behavior of porous Ti-Nb biomaterials.

Eren Yılmaz1, Azim Gökçe2, Fehim Findik3, Hamit Ozkan Gulsoy4, Osman İyibilgin5.   

Abstract

Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16Nb (wt%) alloys containing porosity between 4.05-% and 60.79-% were produced by powder metallurgy using different amounts of space holder materials. The samples were sintered at 1200 °C for 3 h in a high-level vacuum. The effects of the space holder content - in terms of mechanical properties, amount and morphology of the pores, density and the corrosion behavior of the Ti16Nb alloy - were investigated. It is seen that the addition of 70 vol% space holder materials to the Ti16Nb alloy leads to a decrease in the density value from 4.67 g/cm3 to 1.91 g/cm3. Also, it is observed that by producing Ti16Nb with 70 vol% space holder, elastic modulus, compressive and transverse rupture strength values decreased from 96 GPa to 15 GPa, from 1450 MPa to 100 MPa, and from 1173 MPa to 97 MPa, respectively. Although Ti16Nb porous alloys are designed by imitating the properties of the cortical bone for use in the production of load-bearing implants, it is seen that increasing the amount of pores causes, an increase in the corrosion rate and the corrosion current density and a decrease in the polarization resistance.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomaterials; Corrosion; Mechanical properties; Porosity; Titanium alloys

Mesh:

Substances:

Year:  2018        PMID: 30041140     DOI: 10.1016/j.jmbbm.2018.07.018

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

1.  Corrosion and wear behaviour of highly porous Ti-TiB-TiNx in situ composites in simulated physiological solution.

Authors:  Fatih Toptan
Journal:  Turk J Chem       Date:  2020-06-01       Impact factor: 1.239

Review 2.  A Review of Anodized TiNbSn Alloys for Improvement in Layer Quality and Application to Orthopedic Implants.

Authors:  Yu Mori; Naoya Masahashi; Toshimi Aizawa
Journal:  Materials (Basel)       Date:  2022-07-22       Impact factor: 3.748

3.  Fabrication of porous-Ti6Al4V alloy by using hot pressing technique and Mg space holder for hard-tissue biomedical applications.

Authors:  N Aslan; B Aksakal; F Findik
Journal:  J Mater Sci Mater Med       Date:  2021-06-30       Impact factor: 3.896

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.