Literature DB >> 30041124

Comparison of several third-order correction algorithms applied to fluorescence excitation-emission-sample data array: Interference-free determination of polycyclic aromatic hydrocarbons in water pollution.

Zhe Yang1, Tingting Liu2, Yutian Wang1, Yuanyuan Yuan1, Fengkai Shang1.   

Abstract

Interference-free determination of polycyclic aromatic hydrocarbons (PAHs) in water pollution is proposed based on third-order correction algorithms with quadrilinear component modeling applied to the constructed four way fluorescence excitation-emission-sample data array with higher accuracy and better predictive ability than second-order (three-dimension) correction. Alternating weighted residue constraint quadrilinear decomposition (AWRCQLD), quadrilinear parallel factor analysis (4-PARAFAC), alternate penalty quadrilinear decomposition (APQLD) and alternate penalty trilinear decomposition (APTLD) are applied to acenaphthene (ANA), naphthalene (NAP) and fluorene (FLU) respectively. Fulvic acid affects PAHs determination seriously in real-world situation, so it is simulated as an interfering agent. Excitation-emission fluorescence matrixes (EEMs) of PAHs are measured at different volumes of fulvic acid simulated different interference conditions, to construct a four-way data array. After the four-way spectra data is analyzed by AWRCQLD, 4-PARAFAC, and APQLD, three-way EEMs analyzed by APTLD, results show that, on the one hand, PAHs can be measured more accurately with four-way data combined with third-order calibration than lower-order. On the other hand, AWRCQLD algorithm can reflect the superiority of third-order advantage better with higher recovery rate and smaller root mean square error, than other third-order or second-order correction algorithms.
Copyright © 2018. Published by Elsevier B.V.

Entities:  

Keywords:  Alternating weighted residue constraint quadrilinear decomposition; Four-way spectral data; Polycyclic aromatic hydrocarbons; Spectra; Three-dimension fluorescence

Year:  2018        PMID: 30041124     DOI: 10.1016/j.saa.2018.07.045

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  1 in total

1.  Low-temperature time-resolved phosphorescence excitation emission matrices for the analysis of phenanthro-thiophenes in chromatographic fractions of complex environmental extracts.

Authors:  Sadia Arif; Maha Al-Tameemi; Walter B Wilson; Stephen A Wise; Fernando Barbosa; Andres D Campiglia
Journal:  Talanta       Date:  2020-02-06       Impact factor: 6.057

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.