| Literature DB >> 30040785 |
Carrie Scheel1, Jim Mecham2, Vic Zuccarello2, Ryan Mattes1.
Abstract
BACKGROUND: OccuPro's functional capacity evaluation (FCE) is used for assessing the client's readiness to return to work and three separate intra-rater and inter-rater reliability studies are explored here.Entities:
Keywords: Return to work; industrial rehabilitation; kinesiophysical; material handling; workers’ compensation
Mesh:
Year: 2018 PMID: 30040785 PMCID: PMC6087436 DOI: 10.3233/WOR-182754
Source DB: PubMed Journal: Work ISSN: 1051-9815
OccuPro Decision Charts
| Avoid | Occasional | Frequent | Constant | ||
| Simple Grasping | Ability | Client is unable to generate any poundage on dynamometer | Client able to generate some poundage on dynamometer | Client able to achieve grip strength that is within normal age and gender ranges per Matheowitz norms | Male clients are able to achieve grip strength that is within 21 points of their mean and female clients are within 12 points of their mean or greater per Matheowitz age and gender norms |
| Mechanics | Clientdemonstratesmechanical deficits to include but not limited to significant loss of distal upper extremity range of motion. | Client demonstrates mechanical changes to include but not limited to distal upper extremity range of motion. | Client demonstrates no loss of distal upper extremity mechanics | Client demonstrates no loss of distal upper extremity mechanics | |
| Functional Pain | Client understands and appropriately uses the OccuPro pain intensity scale, has minimal to no reliability of pain issues and reports increases in pain symptoms toa6or higher specifically associated with the distal upper extremity. | Client understands and appropriately uses the OccuPro pain intensity scale, has minimal to no reliability of pain issues, and reports pain at 5 or less specifically associated with the distal upper extremity. | Client understands and appropriately uses the OccuPro pain intensity scale, has minimal to no reliability of pain issues and reports pain at a 4 or less specifically associated with the distal upper extremity. | Client understands and appropriately uses the OccuPro pain intensity scale, has minimal to no reliability of pain issues and reports pain symptoms at a 2.5 or less specifically associated with the distal upper extremity. | |
| Pain Behav¬iors | Client exhibits significant facial grimacing, verbal grunting, holding, and/or requires a break following this test and is specifically associated with pain in the distal upper extremity. | Client exhibits mild pain behaviors including but not limited to facial grimacing and is specifically associated with pain in the distal upper extremity. | Client exhibits no pain behaviors specifically associated with pain in the distal upper extremity. | Client exhibits no pain behaviors specifically associated with pain in the distal upper extremity. | |
| Functional Demon¬stration | Client exhibits an inability to perform material handling activities secondary to functional grip strength | Client exhibited the ability to perform occasional material handling activities at low weight levels | Client exhibited the ability to perform all occasional and frequent material handling activities at low weight levels | Client exhibited the ability to perform all material handling activities without deficit |
Inter-rater reliability
| Subtest | ICC Value | |
|---|---|---|
| Firm Grasping | 0.916 | *0.000 |
| Simple Grasping | 0.828 | *0.000 |
| Pinching | 0.656 | *0.003 |
| Fine Motor Coordination | 0.756 | *0.000 |
| Gross Motor Coordination | 0.931 | *0.000 |
| Occasional Squat Lift | 0.804 | Not Reported |
| Frequent Squat Lift | 0.869 | Not Reported |
| Occasional Power Lift | 0.738 | Not Reported |
| Frequent Power Lift | 0.747 | Not Reported |
| Occasional Carrying | 0.804 | Not Reported |
| Frequent Carrying | 0.849 | Not Reported |
*P value is statistically significant (<0.05).
Intra-rater reliability
| Subtest | ICC Value | |
|---|---|---|
| Occasional Squat Lift | 0.948 | *0.000 |
| Frequent Squat Lift | 0.854 | *0.000 |
| Occasional Power Lift | 0.975 | *0.000 |
| Frequent Power Lift | 0.932 | *0.000 |
| Occasional Carrying | 0.924 | *0.000 |
| Frequent Carrying | 0.927 | *0.000 |
*P value is statistically significant (<0.05).