Literature DB >> 30040633

A Parametric Level Set-Based Approach to Difference Imaging in Electrical Impedance Tomography.

Dong Liu, Danny Smyl, Jiangfeng Du.   

Abstract

This paper presents a novel difference imaging approach based on the recently developed parametric level set (PLS) method for estimating the change in a target conductivity from electrical impedance tomography measurements. As in conventional difference imaging, the reconstruction of conductivity change is based on data sets measured from the surface of a body before and after the change. The key feature of the proposed approach is that the conductivity change to be reconstructed is assumed to be piecewise constant, while the geometry of the anomaly is represented by a shape-based PLS function employing Gaussian radial basis functions (GRBFs). The representation of the PLS function by using GRBF provides flexibility in describing a large class of shapes with fewer unknowns. This feature is advantageous, as it may significantly reduce the overall number of unknowns, improve the condition number of the inverse problem, and enhance the computational efficiency of the technique. To evaluate the proposed PLS-based difference imaging approach, results obtained via simulation, phantom study, and in vivo pig data are studied. We find that the proposed approach tolerates more modeling errors and leads to a significant improvement in image quality compared with the conventional linear approach.

Entities:  

Year:  2018        PMID: 30040633     DOI: 10.1109/TMI.2018.2857839

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Simultaneous Imaging of Bio- and Non-Conductive Targets by Combining Frequency and Time Difference Imaging Methods in Electrical Impedance Tomography.

Authors:  Xue Bai; Dun Liu; Jinzhao Wei; Xu Bai; Shijie Sun; Wenbin Tian
Journal:  Biosensors (Basel)       Date:  2021-05-31

2.  Reconstruction of conductivity distribution with electrical impedance tomography based on hybrid regularization method.

Authors:  Yanyan Shi; Xiaoyue He; Meng Wang; Bin Yang; Feng Fu; Xiaolong Kong
Journal:  J Med Imaging (Bellingham)       Date:  2021-06-17

3.  Removing Clinical Motion Artifacts During Ventilation Monitoring With Electrical Impedance Tomography: Introduction of Methodology and Validation With Simulation and Patient Data.

Authors:  Lin Yang; Shuoyao Qu; Yanwei Zhang; Ge Zhang; Hang Wang; Bin Yang; Canhua Xu; Meng Dai; Xinsheng Cao
Journal:  Front Med (Lausanne)       Date:  2022-01-31

4.  Introduction of Sample Based Prior into the D-Bar Method Through a Schur Complement Property.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Jari P Kaipio; Jennifer L Mueller; Raul Gonzalez Lima
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 11.037

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.