Literature DB >> 30039915

The micromechanical behavior of implant-abutment connections under a dynamic load protocol.

Holger Zipprich1, Paul Weigl1, Christoph Ratka1, Bodo Lange1, Hans-Christoph Lauer1.   

Abstract

BACKGROUND: The implant-abutment connection (IAC) is known to be a key factor for the long-term stability of peri-implant tissue.
PURPOSE: The aim of the present in vitro study was to detect and measure the mechanical behavior of different IACs by X-ray imaging.
MATERIALS AND METHODS: A total of 20 different implant systems with various implant dimensions and IACs (13 conical-, 6 flat-, and 1 gable-like IAC) have been tested using a chewing device simulating dynamic and static loading up to 200 N. Micromovements have been recorded with a high-resolution, high-speed X-ray camera, and gap length and gap width between implant and abutment have been calculated. Furthermore, X-ray video sequences have been recorded to investigate the sealing capacity of different IACs.
RESULTS: Out of the 20 implant systems, eight implant systems with a conical IAC showed no measurable gaps under static and dynamic loading (200 N). By contrast, all investigated implant systems with a flat IAC showed measurable gaps under dynamic and static loading. X-ray video sequences revealed that a representative conical IAC had sufficient sealing capacity.
CONCLUSION: Within the limits of the present in vitro study, X-ray imaging showed reduced formation of microgaps and consecutive micromovements in implants with conical IAC compared to flat IACs.
© 2018 Wiley Periodicals, Inc.

Keywords:  contamination; cyclic load; dynamic load; fatigue; implant-abutment connection; microleakage; micromovement; static load

Mesh:

Year:  2018        PMID: 30039915     DOI: 10.1111/cid.12651

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  Conical connection adjustment in prosthetic abutments obtained by different techniques.

Authors:  Roser Camós-Tena; Tomás Escuin-Henar; Sergi Torné-Duran
Journal:  J Clin Exp Dent       Date:  2019-05-01

Review 2.  The effect of implant-abutment connections on peri-implant bone levels around single implants in the aesthetic zone: A systematic review and a meta-analysis.

Authors:  Caroliene M Meijndert; Gerry M Raghoebar; Arjan Vissink; Konstantina Delli; Henny J A Meijer
Journal:  Clin Exp Dent Res       Date:  2021-08-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.