Literature DB >> 30037573

Intraoperative Preconditioning of Fixed and Adjustable Loop Suspensory Anterior Cruciate Ligament Reconstruction With Tibial Screw Fixation-An In Vitro Biomechanical Evaluation Using a Porcine Model.

Benjamin C Noonan1, Samuel Bachmaier2, Coen A Wijdicks3, Asheesh Bedi4.   

Abstract

PURPOSE: To evaluate the effect of preconditioning according to intraoperative workflow on initial tension and elongation behavior for femoral adjustable loop devices (ALDs) and closed loop devices (CLDs) in suspensory anterior cruciate ligament reconstruction (ACLR) with tibial screw fixation in a biomechanical in vitro study.
METHODS: Three ACLR groups with tibial screw fixation were biomechanically tested in a full-construct setup using porcine tibias. Groups (n = 8 per group) varied by femoral fixation method and consisted of a CLD (group 3) and ALD fixation with (group 2) and without simulated intraoperative preconditioning (group 1). The change in tension after screw insertion and the displacement to restore the initial loading situation were measured. Grafts underwent dynamic cycling (1,000 cycles at 0.75 Hz) using both a position and a force control mode.
RESULTS: Data are presented as mean [standard deviation]. Placement of an interference screw induced a graft tension loss of 62% (49.4 [0.4] N vs 19.0 [10.0] N, P < .001) by introducing a laxity of 0.53 [0.26] mm. Intraoperative preconditioning led to a higher initial load level (228.3 [19.8] N) compared with unconditioned ALD (156.1 [25.5] N, P < .001) and CLD groups (156.6 [12.8] N, P < .001) with less force decrease over position-controlled cyclic loading. Furthermore, initial (-0.22 [0.16] mm) and dynamic elongation (0.88 [0.23] mm) were reduced compared with the unconditioned ALD (0.65 [0.35] mm, P < .001; and 1.56 [0.19] mm, P < .001) and CLD groups (0.16 [0.26] mm, P < .001; and 1.64 [0.24] mm, P < .001).
CONCLUSIONS: ACLR with femoral ALD fixation and intraoperative preconditioning allows for restoration of time-zero screw-imparted slack and leads to significantly reduced cyclic elongation in accordance with native ACL function. Both ALD and CLD control groups behaved similarly, with total elongation less than 3 mm including time-zero slack. CLINICAL RELEVANCE: Although the clinical relevance of time-zero graft tension loss is uncertain, the use of an ALD in concert with tibial screw fixation may be favorable to allow for tension optimization.
Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30037573     DOI: 10.1016/j.arthro.2018.04.014

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

1.  Flexion deformity and laxity as a function of knee position at the time of tensioning of rigid anatomic hamstring ACL grafts.

Authors:  Peter J C McEwen; Milford McArthur; Sarah G Brereton; William B O'Callaghan; Matthew P R Wilkinson
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2020-10-07

2.  Ulnar Collateral Ligament Reconstruction Technique Utilizing Suture Tape Augmentation.

Authors:  Roddy McGee; Adam Eudy; Victor Hoang; Shivali Gupta; Ashley Jacks; Serena Bruhn
Journal:  Arthrosc Tech       Date:  2020-01-23

3.  Treatment of Acute Proximal Anterior Cruciate Ligament Tears-Part 1: Gap Formation and Stabilization Potential of Repair Techniques.

Authors:  Samuel Bachmaier; Gregory S DiFelice; Bertrand Sonnery-Cottet; Wiemi A Douoguih; Patrick A Smith; Lee J Pace; Daniel Ritter; Coen A Wijdicks
Journal:  Orthop J Sports Med       Date:  2020-01-29
  3 in total