Cytotoxicity of long-term denture base materials.

Merve Çakırbay Tanış1, Canan Akay2, Handan Sevim3.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the cytotoxic effect of various denture base materials following four different aging periods.
METHODS: In total, 48 disc-shaped specimens per each group were prepared: Group I: acrylic resin polymerized in cool water and heated up to 100°C over 45 min and boiled for 15 min; Group II: acrylic resin polymerized under pressure in 40°C-45°C water bath for 10 min; Group III: autopolymerized hard relining resin Cold Liner Rebase; Group IV: autopolymerized hard relining resin Truliner; Group V: soft relining resin DentuSil. Then the specimens were stored in water for 24 h or 15 days, or thermocycled 2500 times or 10,000 times. Cytotoxicity was evaluated with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay using L929 cells after 72-h cell incubation. Cell viability percentages were counted and statistical analyses were performed. The results were also evaluated according to ISO standard 10993-5.
RESULTS: All materials showed similar cell viability percentages following 24-h water storage and 2500 and 10,000 thermal cycles. Following 15-day water storage, a statistically significant difference was observed between the materials. Comparisons of the aging periods for each material showed statistically significant differences. Groups III and IV showed moderately cytotoxic effect following 15-day water storage. The remaining groups showed slightly cytotoxic or non-cytotoxic effect. DISCUSSION: Polymerizing acrylic resins under pressure can be an alternative to conventional polymerizing to ensure a faster denture repair while providing similar cell viability values. Heat-cured acrylic resins provide higher cell viability than hard chairside lining materials in a 15-day period.

Entities:  

Keywords:  Acrylic resin; cytotoxicity; hard liner; soft liner; thermal cycle

Mesh:

Substances:

Year:  2018        PMID: 30033859     DOI: 10.1177/0391398818786884

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  2 in total

1.  Toxicological Assessment of an Acrylic Removable Orthodontic Appliance Using 2D and 3D In Vitro Methods.

Authors:  Stefania Dinu; Emanuela Lidia Craciunescu; Ioana Macasoi; Doina Chioran; Mircea Rivis; Daliborca Vlad; Raluca Adriana Milutinovici; Iasmina Marcovici; Alina Dolghi; Alina Moaca; Dorin Cristian Dinu; Cristina Dehelean; Malina Popa
Journal:  Materials (Basel)       Date:  2022-02-04       Impact factor: 3.623

2.  Evaluation of the In-Vitro Cytotoxicity of Heat Cure Denture Base Resin Modified with Recycled PMMA-Based Denture Base Resin.

Authors:  Divya Krishnamoorthi; Suma Karthigeyan; Seyed Asharaf Ali; Sasikala Rajajayam; Ramya Gajendran; Mithra Rajendran
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.