Abstract

Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical aortic valve replacement (SAVR) in high-risk elderly patients with calcified aortic valve disease. All currently FDA-approved TAVR devices use tissue valves that were adapted to but not specifically designed for TAVR use. Emerging clinical evidence indicates that these valves may get damaged during crimping and deployment- leading to valvular calcification, thrombotic complications, and limited durability. This impedes the expected expansion of TAVR to lower-risk and younger patients. Viable polymeric valves have the potential to overcome such limitations. We have developed a polymeric SAVR valve, which was optimized to reduce leaflet stresses and offer a thromboresistance profile similar to that of a tissue valve. This study compares the polymeric SAVR valve's hemodynamic performance and mechanical stresses to a new version of the valve- specifically designed for TAVR. Fluid-structure interaction (FSI) models were utilized and the valves' hemodynamics, flexural stresses, strains, orifice area, and wall shear stresses were compared. The TAVR valve had 42% larger opening area and 27% higher flow rate versus the SAVR valve, while wall shear stress distribution and mechanical stress magnitudes were of the same order, demonstrating the enhanced performance of the TAVR valve prototype. The TAVR valve FSI simulation and Vivitro pulse duplicator experiments were compared in terms of the leaflets' kinematics and the effective orifice area. The numerical methodology presented can be further used as a predictive tool for valve design optimization for enhanced hemodynamics and durability.

Entities:  

Year:  2018        PMID: 30029207     DOI: 10.1115/1.4040600

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  6 in total

Review 1.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

2.  Designing a Novel Asymmetric Transcatheter Aortic Valve for Stenotic Bicuspid Aortic Valves Using Patient-Specific Computational Modeling.

Authors:  Ryan T Helbock; Salwa B Anam; Brandon J Kovarovic; Marvin J Slepian; Ashraf Hamdan; Rami Haj-Ali; Danny Bluestein
Journal:  Ann Biomed Eng       Date:  2022-08-30       Impact factor: 4.219

3.  Fluid-Structure Interaction Analysis on the Influence of the Aortic Valve Stent Leaflet Structure in Hemodynamics.

Authors:  Xiangkun Liu; Wen Zhang; Ping Ye; Qiyi Luo; Zhaohua Chang
Journal:  Front Physiol       Date:  2022-05-13       Impact factor: 4.755

4.  Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis.

Authors:  Ram P Ghosh; Gil Marom; Matteo Bianchi; Karl D'souza; Wojtek Zietak; Danny Bluestein
Journal:  Biomech Model Mechanobiol       Date:  2020-02-24

5.  In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve.

Authors:  Oren M Rotman; Brandon Kovarovic; Matteo Bianchi; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2020-02       Impact factor: 3.826

6.  New insights into mitral heart valve prolapse after chordae rupture through fluid-structure interaction computational modeling.

Authors:  Andrés Caballero; Wenbin Mao; Raymond McKay; Charles Primiano; Sabet Hashim; Wei Sun
Journal:  Sci Rep       Date:  2018-11-23       Impact factor: 4.379