| Literature DB >> 30025086 |
Andrew D Pucker1, Bradley E Dougherty2, Lisa A Jones-Jordan2, Justin T Kwan3, Carolina M E Kunnen4, Sruthi Srinivasan5.
Abstract
Purpose: This study reports on the ability of the Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire to detect dry eye (DE) symptoms in contact lens (CL) and non-CL wearers.Entities:
Mesh:
Year: 2018 PMID: 30025086 PMCID: PMC6733533 DOI: 10.1167/iovs.18-24016
Source DB: PubMed Journal: Invest Ophthalmol Vis Sci ISSN: 0146-0404 Impact factor: 4.799
Demographics Information of Sample
| Subjects, | 150 | 134 |
| Age, y | 34.5 ± 12.6 | 40.6 ± 15.1 |
| Female, % | 66.7 | 55.3 |
| Ethnicity | ||
| White, % | 63.3 | 72.4 |
| African American, % | 0.7 | 4.5 |
| Asian, % | 30.7 | 18.7 |
| Other, % | 5.3 | 3.5 |
Clinical Signs and Symptoms
| TMH, mm | 0.22 ± 0.11 | 0.27 ± 0.12 | 0.0004 |
| PRT, mm | 4.34 ± 5.08 | 3.93 ± 3.80 | 0.43 |
| Self-reported DE, % | 36.9 | 39.1 | 0.71 |
| Self-reported MGD, % | 19.6 | 17.3 | 0.65 |
| Diagnosed DE, % | 66.7 | 55.2 | 0.052 |
| SPEED 8-item sum score | 7.4 ± 4.7 | 7.3 ± 5.0 | NA |
| SPEED 8-item Rasch score* | 30.6 ± 14.1 | 30.2 ± 14.5 | 0.82 |
| CLDEQ-8 sum score | 13.3 ± 6.6 | NA | NA |
| CLDEQ-8 Rasch score* | 47.4 ± 11.4 | NA | NA |
| CLDEQ 4-item sum score | 7.6 ± 3.8 | NA | NA |
| CLDEQ 4-item Rasch score* | 42.6 ± 20.6 | NA | NA |
Logits were converted to a 0 to 100 scale. Values of P < 0.05 were considered significantly different.
Rasch Analysis Summary Statistics for the Full SPEED and SPEED-8 Questionnaires, CLDEQ-4, and CLDEQ-8
| SPEED (all items) | 43.0 (0.2) | 43.4 (2.5) | 0.42 | 0.99 | 1.0 | 7.7 |
| SPEED (8-item short form) | 30.4 (0.8) | 48.0 (2.0) | 2.03 | 0.98 | 1.0 | 2.4 |
| CLDEQ-8 | 47.2 (1.0) | 54.4 (1.8) | 2.40 | 0.97 | 1.0 | 2.2 |
| CLDEQ (4-item short form) | 42.6 (1.6) | 53.7 (2.8) | 2.55 | 0.96 | 0.99 | 1.6 |
SPEED-8 Questionnaire Scores by Self-Reported DE Status
| Dry eye ( | 38.45 ± 10.93 | 38.11 ± 10.09 | 38.81 ± 11.84 |
| No dry eye ( | 25.56 ± 13.63 | 25.99 ± 14.11 | 25.06 ± 13.13 |
Positive and negative groups were significantly different for all conditions (P < 0.001). Rasch analysis was scaled to make all scores a maximum of 100.
SPEED-8 Questionnaire Scores by Self-Reported MGD Status
| Meibomian gland dysfunction ( | 38.76 ± 10.33 | 36.49 ± 10.44 | 41.62 ± 9.66 |
| No meibomian gland dysfunction ( | 28.50 ± 14.19 | 28.87 ± 14.40 | 28.09 ± 14.01 |
Positive and negative groups were significantly different for all conditions (all P values < 0.002). Rasch analysis was scaled to make all scores a maximum of 100.
Correlations Between SPEED-8 Questionnaire Scores and Clinical Factors
| SPEED-8 | ||||||
| Correlation coefficient | 1.000 | 0.007 | 0.004 | |||
| N/A | 0.901 | 0.943 | ||||
| Subjects, | 284 | 283 | 283 | |||
| Self-reported DE | ||||||
| Correlation coefficient | 1.000 | −0.011 | 0.036 | |||
| N/A | 0.851 | 0.553 | ||||
| Subjects, | 282 | 281 | 281 | |||
| Self-reported MGD | ||||||
| Correlation coefficient | 1.000 | 0.001 | 0.072 | |||
| N/A | 0.989 | 0.230 | ||||
| Subjects, | 281 | 280 | 280 | |||
| TMH | ||||||
| Correlation coefficient | 1.000 | 0.093 | ||||
| N/A | 0.120 | |||||
| Subjects, | 283 | 283 | ||||
| PRT Test | ||||||
| Correlation coefficient | 1.000 | −0.060 | ||||
| N/A | 0.317 | |||||
| Subjects, | 283 | 283 | ||||
| Diagnosed DE | ||||||
| Correlation coefficient | 1.000 | |||||
| N/A | ||||||
| Subjects, | 284 | |||||
Significant (P < 0.05) correlations are shown in bold.
Correlations Between CLDEQ-4 and Clinical Factors
| CLDEQ-4 | ||||||
| Correlation coefficient | 1.000 | 0.025 | 0.088 | |||
| N/A | 0.765 | 0.283 | ||||
| Subjects, | 150 | 150 | 150 | |||
| Self-reported DE | ||||||
| Correlation coefficient | 1.000 | −0.011 | 0.36 | |||
| N/A | 0.851 | 0.553 | ||||
| Subjects, | 281 | 281 | 281 | |||
| Self-reported MGD | ||||||
| Correlation coefficient | 0.001 | 0.072 | ||||
| 0.989 | 0.230 | |||||
| Subjects, | 280 | 280 | ||||
| TMH | ||||||
| Correlation coefficient | 1.000 | 0.93 | ||||
| N/A | 0.120 | |||||
| Subjects, | 283 | 283 | ||||
| PRT Test | ||||||
| Correlation coefficient | 1.000 | −0.060 | ||||
| N/A | 0.317 | |||||
| Subjects, | 283 | 283 | ||||
| Diagnosed DE | ||||||
| Correlation coefficient | 1.000 | |||||
| N/A | ||||||
| Subjects, | 284 | |||||
Significant (P < 0.05) correlations are shown in bold.