Jonathan P Evans1,2,3,4, Jeremy Metz5, Rahul Anaspure6, William J Thomas6, Andrew King6, Vicki A Goodwin7, Chris D Smith6.
Abstract
BACKGROUND: Injections into the tendinous portion of the common extensor origin are a common intervention in the treatment of Lateral Elbow Tendinopathy (LET). Clinical trials report a heterogeneous selection of injectate volumes and delivery techniques, with systematic reviews finding no clear consensus. The aim of this study was to assess the intratendinous distribution and surrounding tissue contamination of ultrasound-guided injections into the Common Extensor Tendon (CET) of the elbow.Entities:
Year: 2018 PMID: 30022381 PMCID: PMC6051955 DOI: 10.1186/s40634-018-0142-8
Source DB: PubMed Journal: J Exp Orthop ISSN: 2197-1153
Fig. 1Longitudinal ultrasonogram of the Common Extensor Tendon (CET). The hypodermic needle can been seen entering at the right side of the image. This particular specimin underwent a 1 ml single shot injection
Fig. 2Dissected Common Extensor Tendon (CET). Showing non-articular side. Blue colouration from methylene blue dye injection
Fig. 3Common Extensor Tendon (CET) held in wax surround of bench microtome. The four areas of algorithmically derived colour intensity are seen within each of the four contour lines
Mean percentage +/− Standard deviation (SD) of the Blue pixels distributed within the CET tendon from lightest blue to darkest blue in four groups of blue colour graduation (lightest blue = group 1, darkest blue = group 4))
| Injection Group | Blue pixel distribution | |||||||
|---|---|---|---|---|---|---|---|---|
| Lightest blue ←→ Darkest blue | ||||||||
| Group 1 | Group 2 | Group 3 | Group 4 | |||||
| Mean | SD | Mean | SD | Mean | SD | Mean | SD | |
| 1 ml | 98.76% | 2.00% | 94.00% | 4.01% | 79.55% | 7.49% | 44.04% | 12.54% |
| 3 ml | 97.91% | 2.27% | 90.87% | 7.92% | 74.98% | 12.59% | 37.83% | 15.30% |
| Single shot | 98.63% | 1.96% | 92.04% | 7.26% | 74.86% | 11.25% | 39.21% | 10.29% |
| Fenestrated | 98.05% | 2.35% | 92.82% | 5.59% | 79.67% | 9.32% | 42.66% | 17.33% |
Fig. 4a Bar chart showing the mean percentage of blue pixels in each of the four colour intensity groups for the 1 ml and 3 ml volume injections. Error Bars = 95% Confidence Intervals. b Bar chart showing the mean percentage of blue pixels in each of the four colour intensity groups for the single injection and fenestrated injection techniques. Error Bars = 95% Confidence Intervals
Fig. 5Examples of 3-Dimensional reformats of tendon segments for the four injection techniques. From left – tendon boarder, then working through four colour intensity contours. Note no pattern of pooling or longitudinal spread. (Video examples of the four groups of injections are available in the Additional file 1)