Literature DB >> 30020452

Cephalic vs. subclavian lead implantation in cardiac implantable electronic devices: a systematic review and meta-analysis.

Alexander P Benz1, Mate Vamos1, Julia W Erath1, Stefan H Hohnloser1.   

Abstract

AIMS: Cephalic vein cutdown (CVC) and subclavian puncture (SP) are widely used techniques for lead insertion of cardiac implantable electronic devices (CIEDs). Whether one technique is superior to the other, is still being debated. The purpose of this study was to compare CVC vs. SP for lead implantation in CIEDs with respect to the incidence of pneumothorax, lead failure, and bleeding. METHODS AND
RESULTS: We performed a systematic search of the pertinent literature on lead implantation in CIEDs via PubMed and Cochrane databases published over the last 25 years. Standard meta-analytic methods were applied to compare incidences of outcomes of interest. Sensitivity analysis was conducted to determine the impact of each study on the overall effect size. Risk of publication bias was assessed. A total of 20 studies were included in the analysis. These studies comprised more than 30 000 patients with more than 50 000 leads implanted via CVC or SP. The incidence of pneumothorax was lower with the CVC technique (n = 29/15 065, 0.19% vs. n = 205/15 824, 1.30%) [odds ratio (OR) 0.21, 95% confidence interval (CI) 0.10-0.42, P < 0.001]. With respect to overall lead failure, CVC was associated with better outcomes as compared to SP (n = 10/2002, 0.50% vs. n = 40/2080, 1.92%) (OR 0.25, 95% CI 0.13-0.51, P < 0.001). There was no significant difference in bleeding events (n = 25/811, 3.08% vs. n = 20/2136, 0.94%) (OR 1.69, 95% CI 0.37-7.79, P = 0.50).
CONCLUSION: This comprehensive meta-analysis demonstrates lower risk for pneumothorax and lead failure associated with CVC as compared to SP. Cephalic vein cutdown should constitute the preferred venous access.

Entities:  

Mesh:

Year:  2019        PMID: 30020452     DOI: 10.1093/europace/euy165

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  3 in total

Review 1.  Complications in Device Therapy: Spectrum, Prevalence, and Management.

Authors:  J Llewellyn; D Garner; A Rao
Journal:  Curr Heart Fail Rep       Date:  2022-08-06

2.  Vascular Accesses in Cardiac Stimulation and Electrophysiology: An Italian Survey Promoted by AIAC (Italian Association of Arrhythmias and Cardiac Pacing).

Authors:  Matteo Ziacchi; Angelo Placci; Andrea Angeletti; Fabio Quartieri; Cristina Balla; Santo Virzi; Matteo Bertini; Roberto De Ponti; Mauro Biffi; Giuseppe Boriani
Journal:  Biology (Basel)       Date:  2022-02-08

Review 3.  State of the art: leadless ventricular pacing : A national expert consensus of the Austrian Society of Cardiology.

Authors:  C Steinwender; P Lercher; C Schukro; H Blessberger; G Prenner; M Andreas; J Kraus; M Ammer; M Stühlinger
Journal:  J Interv Card Electrophysiol       Date:  2019-12-20       Impact factor: 1.900

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.