Literature DB >> 30020057

Portable Autorefractors for Detecting Axial Length Changes in Space.

Kseniya S Masterova, Allison P Anderson, Devin R Cowan, Abigail M Fellows, Michael E Zegans, Jay C Buckey.   

Abstract

INTRODUCTION: We evaluated the reproducibility of two portable, self-administered autorefractors (Netra and SVOne Pro) to assess the time course of visual changes on the ISS.
METHODS: We measured cycloplegic refractive error at 5 visits at least a week apart in 13 subjects (6 women, 7 men, 30 ± 9 yr) using both devices seated and also prone with lower body positive pressure (LBPP) applied. Axial length was measured with an optical biometer. Subjects completed a questionnaire on device preferences.
RESULTS: The SVOne seated intrasession reproducibility coefficient (RPC) was 0.37 diopters (D), while the Netra's was 0.41 D. Intersession seated results were: RPC = 0.67 D for the SVOne and RPC = 0.54 D for the Netra. The average seated to prone LBPP differences were significantly different from zero for both the SVOne and Netra. The SVOne was preferred in four out of five categories on the questionnaire and took half the time to complete a measurement set compared to the Netra. DISCUSSION: Users preferred the SVOne and it took less time. An SVOne refraction change of 0.67 D from baseline would happen by chance less than 5% of the time. If multiple separate measurements were taken, the detection limit could be reduced (e.g., three repeated measurements could reduce it to 0.38 D). Since astronauts with visual changes show spherical equivalent changes of 0.5 to 1.0 D, in-flight autorefractors could help determine the time course of refractive changes in space from which changes in axial length could be inferred.Masterova KS, Anderson AP, Cowan DR, Fellows AM, Zegans ME, Buckey JC. Portable autorefractors for detecting axial length changes in space. Aerosp Med Hum Perform. 2018; 89(8):724-730.

Entities:  

Mesh:

Year:  2018        PMID: 30020057     DOI: 10.3357/AMHP.5049.2018

Source DB:  PubMed          Journal:  Aerosp Med Hum Perform        ISSN: 2375-6314            Impact factor:   1.053


  3 in total

Review 1.  Spaceflight Associated Neuro-Ocular Syndrome (SANS): A Systematic Review and Future Directions.

Authors:  Yosbelkys Martin Paez; Lucy I Mudie; Prem S Subramanian
Journal:  Eye Brain       Date:  2020-10-19

Review 2.  Portable hardware & software technologies for addressing ophthalmic health disparities: A systematic review.

Authors:  Margarita Labkovich; Megan Paul; Eliott Kim; Randal A Serafini; Shreyas Lakhtakia; Aly A Valliani; Andrew J Warburton; Aashay Patel; Davis Zhou; Bonnie Sklar; James Chelnis; Ebrahim Elahi
Journal:  Digit Health       Date:  2022-05-06

3.  Acute effects of postural changes and lower body positive and negative pressure on the eye.

Authors:  M P Van Akin; O M Lantz; A M Fellows; Christine Toutain-Kidd; Michael Zegans; J C Buckey; A P Anderson
Journal:  Front Physiol       Date:  2022-08-31       Impact factor: 4.755

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.