Literature DB >> 30020056

Quantitative Pupillometry for Detection of Intracranial Pressure Changes During Head-Down Tilt.

Timothy A Soeken, Al Alonso, Aaron Grant, Eusebia Calvillo, Barbara Gutierrez-Flores, Jonathan Clark, Dorit Donoviel, Eric M Bershad.   

Abstract

BACKGROUND: There is a need to develop noninvasive methods to monitor intracranial pressure (ICP). Pupillary reactivity decreases in patients with elevated ICP with demonstrated cerebral edema. We sought to determine whether pupillary reactivity is affected when ICP is elevated in the absence of brain edema.
METHODS: Healthy subjects and individuals with idiopathic intracranial hypertension (IIH) underwent pupillometry in different positions (upright, supine, and head-down tilt) and during different physiological maneuvers. A separate group of healthy subjects were tested in the upright resting position only. The pupillary dynamics were measured with a pupillometer.
RESULTS: Healthy and IIH subjects were enrolled. In the healthy subjects the change from upright to head-down tilt led to a Neurological Pupil Index (NPI) decrease from 4.30 to 4.12, while maximum pupil size and minimum pupil size increased from 4.74 to 5.19 and 3.04 to 3.44, respectively. In the IIH group the maximum pupil size, minimum pupil size, and latency increased in magnitude with a decline in head tilt. The mean NPI of IIH subjects, 4.37, was greater than the healthy mean, 4.25. Also, the mean IIH Max and Min, 5.02 and 3.25, were greater than the healthy mean, 4.62 and 2.92. DISCUSSION: We observed changes in the pupillary reactivity in all subjects based on changes in position and task. There were also differences between the healthy and IIH subjects. This is consistent with our hypothesis that elevated intracranial pressure may result in decreased pupillary reactivity even in the absence of brain edema.Soeken TA, Alonso A, Grant A, Calvillo E, Gutierrez-Flores B, Clark J, Donoviel D, Bershad EM. Quantitative pupillometry for detection of intracranial pressure changes during head-down tilt. Aerosp Med Hum Perform. 2018; 89(8):717-723.

Entities:  

Mesh:

Year:  2018        PMID: 30020056     DOI: 10.3357/AMHP.4929.2018

Source DB:  PubMed          Journal:  Aerosp Med Hum Perform        ISSN: 2375-6314            Impact factor:   1.053


  6 in total

Review 1.  Automated Pupillometry in Neurocritical Care: Research and Practice.

Authors:  Bethany L Lussier; DaiWai M Olson; Venkatesh Aiyagari
Journal:  Curr Neurol Neurosci Rep       Date:  2019-08-23       Impact factor: 5.081

Review 2.  Spaceflight Associated Neuro-Ocular Syndrome (SANS): A Systematic Review and Future Directions.

Authors:  Yosbelkys Martin Paez; Lucy I Mudie; Prem S Subramanian
Journal:  Eye Brain       Date:  2020-10-19

3.  Impact of Increased Intracranial Pressure on Pupillometry: A Replication Study.

Authors:  Sameer Z Al-Obaidi; Folefac D Atem; Sonja E Stutzman; DaiWai M Olson
Journal:  Crit Care Explor       Date:  2019-10-30

4.  Can Quantitative Pupillometry be used to Screen for Elevated Intracranial Pressure? A Retrospective Cohort Study.

Authors:  Jakob Pansell; Robert Hack; Peter Rudberg; Max Bell; Charith Cooray
Journal:  Neurocrit Care       Date:  2022-05-23       Impact factor: 3.532

5.  Quantitative Infrared Pupillometry in Nonconvulsive Status Epilepticus.

Authors:  Jana Godau; Claudia Bierwirth; Johannes Rösche; Julian Bösel
Journal:  Neurocrit Care       Date:  2020-11-20       Impact factor: 3.210

6.  Quantitative assessments of pupillary light reflexes in hospital-onset unresponsiveness.

Authors:  Hyunjo Lee; Soh Hyun Choi; Bobin Park; Yoon-Hee Hong; Han-Bin Lee; Sang-Beom Jeon
Journal:  BMC Neurol       Date:  2021-06-24       Impact factor: 2.474

  6 in total