Literature DB >> 30019228

Robotic laparoendoscopic single-site radical prostatectomy (R-LESS-RP) with daVinci Single-Site® platform. Concept and evolution of the technique following an IDEAL phase 1.

Franco Gaboardi1, Giovannalberto Pini2,3,4, Nazareno Suardi2,4,5, Francesco Montorsi5, Giovanni Passaretti2, Salvatore Smelzo2.   

Abstract

To describe the evolution of robotic laparoendoscopic single-site radical prostatectomy (R-LESS-RP) performed with the daVinci Single-Site Platform® and a home-made multiport aimed to overcome classical drawbacks of LESS, still present with this platform. Between 09/2015 and 06/2017 12 patients underwent R-LESS RP for clinical localized prostate cancer. Following a "phase 1 (development-stage)" innovation, development, exploration, assessment, long-term study (IDEAL) framework, different solutions were drawn to overcome drawbacks of daVinci Single-Site Platform®, included 3 (A, B, and C) multi-ports developed and evaluated in term of advantages/drawbacks concerning ergonomy. The end points of this study were: feasibility, safety, efficacy, by reporting rational description of multiports configuration, demographics, perioperative variables, functional and oncological results. Semi-flexible robotic 5-mm needle-holder instead of Maryland forceps, 30° lenses up and barbed-suture allowed overcoming limits of robotic-platform. Multiport-C (GelPOINT Advanced-Access® and an extra 8-mm robotic trocar outside the multiport) showed the best compromise to ensure both surgeon and bed-side assistant to reproduce a standard robotic procedure. No conversion to either standard robotic or open technique or intraoperative complications occur in any case. Two patients experienced "high-grade" Clavien-Dindo complications. After 12.4 months follow-up, all patients were continent without any sign of biochemical relapse and among 5 preoperative potent patients submitted to nerve-sparing dissection, 4 reported good erectile-function. R-LESS-RP is feasible and safe in the hands of experienced minimally-invasive surgeons. Do date, we recommend a hybrid solution with a home-made multiport and use of an additional standard robotic trocar which allows the use endowrist® technology instruments.

Entities:  

Keywords:  LESS; Laparoendoscopic single site surgery; Prostate cancer; Robot-assisted radical prostatectomy; Robotic surgery

Mesh:

Year:  2018        PMID: 30019228     DOI: 10.1007/s11701-018-0839-9

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  7 in total

1.  Single-port robotic surgery: the next generation of minimally invasive urology.

Authors:  Ryan W Dobbs; Whitney R Halgrimson; Susan Talamini; Hari T Vigneswaran; Jessica O Wilson; Simone Crivellaro
Journal:  World J Urol       Date:  2019-08-28       Impact factor: 4.226

Review 2.  The robotic single-port platform for gynecologic surgery: a systematic review of the literature and meta-analysis.

Authors:  Vito Andrea Capozzi; Giulia Armano; Andrea Rosati; Alessandro Tropea; Antonio Biondi
Journal:  Updates Surg       Date:  2020-05-29

Review 3.  Robotic Surgery Techniques to Improve Traditional Laparoscopy.

Authors:  Tovah Williamson; Sang-Eun Song
Journal:  JSLS       Date:  2022 Apr-Jun       Impact factor: 1.789

Review 4.  Single port robotic radical prostatectomy: a systematic review.

Authors:  Andrew Lai; Ryan W Dobbs; Susan Talamini; Whitney R Halgrimson; Jessica O Wilson; Hari T Vigneswaran; Simone Crivellaro
Journal:  Transl Androl Urol       Date:  2020-04

5.  A Novel RGB-D SLAM Algorithm Based on Cloud Robotics.

Authors:  Yanli Liu; Heng Zhang; Chao Huang
Journal:  Sensors (Basel)       Date:  2019-12-01       Impact factor: 3.576

Review 6.  Robot-assisted radical prostatectomy: Advancements in surgical technique and perioperative care.

Authors:  Isaac Palma-Zamora; Firas Abdollah; Craig Rogers; Wooju Jeong
Journal:  Front Surg       Date:  2022-09-27

Review 7.  Outcome selection, measurement and reporting for new surgical procedures and devices: a systematic review of IDEAL/IDEAL-D studies to inform development of a core outcome set.

Authors:  R C Macefield; N Wilson; C Hoffmann; J M Blazeby; A G K McNair; K N L Avery; S Potter
Journal:  BJS Open       Date:  2020-10-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.