Literature DB >> 30018835

Arthroscopic Osteosynthesis for the Treatment of Coronoid Process Fractures: A Case Series.

Noriaki Shimada1, Katsuhiko ShirakiIt1, Kazuo Saita1.   

Abstract

The treatment strategy and surgical indication for coronoid process fractures are not clear. Many methods of surgery have been described. We report on the use of arthroscopic osteosynthesis for this type of fracture. This method is minimally invasive and effective for confirming the reduction, and it is advantageous for postoperative pain and early recovery after surgery.

Entities:  

Year:  2018        PMID: 30018835      PMCID: PMC6029437          DOI: 10.1155/2018/8512963

Source DB:  PubMed          Journal:  Case Rep Orthop        ISSN: 2090-6757


1. Introduction

Fractures of the ulna coronoid process are relatively rare and are reported to occur in 2%–10% of patients who have a dislocated elbow [1]. The ulna coronoid process is of critical importance to the elbow stability [2, 3]; however, the treatment strategy and surgical indication are not clear. Because the fracture site is deep within the tissue, open reduction internal fixation of the fracture is invasive and difficult. We report on the use of arthroscopic osteosynthesis for the fracture. The arthroscopic approach offers many advantages, including a smaller incision, easy access to the joint and fracture site, less soft tissue dissection, and reduced postoperative pain. This method is minimally invasive and effective for confirming the reduction. The purpose of this report was to present the technique of arthroscopic osteosynthesis in the coronoid process fractures and the clinical results of patients who underwent this surgery.

2. Case Presentation

Informed consent was obtained from all patients who took part in this report.

2.1. Case 1

A 39-year-old man fell and injured himself whilst walking on the road. Upon physical examination, he complained of severe pain in his right elbow, which showed swelling and tenderness. Because of the pain, the range of motion of the elbow joint was limited to 30°–50°. Radiographs revealed a fracture of the ulna coronoid process, which was displaced by about 4 mm (Figure 1). He was diagnosed with a coronoid process fracture, Regan-Morrey type 2. He was young, highly active, and wanted an early return to normal life; therefore, we performed a minimally invasive arthroscopic osteosynthesis 7 days after the injury.
Figure 1

Case 1: radiograph demonstrates a type 2 coronoid fracture.

Surgery was performed under general anaesthesia with the patient in the prone position. We confirmed the fracture site through the anterolateral portal (Figure 2). A shaver and radiofrequency probe were used to remove any clots and debris. The radiofrequency probe allowed us to reduce the amount of bone fragment entering the fracture bed. Under fluoroscopic control, a guide pin for a cannulated cancellous screw (CCS) was inserted from the posterior ulnar shaft into the coronoid fragment (Figure 3). We fixed the fracture with a 3.5 mm CCS and two 1.5 mm K-wires, whilst confirming the anatomical reduction arthroscopically (Figure 4). After fixation, we confirmed a good reduction position and sufficient stability upon examination. We also confirmed a reduction by radiographs (Figure 5). Postoperatively, he wore an immobilizing splint for 1 week and then began physical therapy to increase the range of motion. After 3 weeks, the K-wires were removed, and bone union was achieved after 4 months (Figure 6). At 1 year postoperatively, he had no pain and a physical examination revealed a complete range of motion.
Figure 2

Case 1: arthroscopic photograph shows the fracture site (arrow). R: radial head; U: ulna (fracture bed); C: coronoid process.

Figure 3

Case 1: a guide pin is inserted from the posterior side.

Figure 4

Case 1: arthroscopic photograph shows a good reduction position after fixation by a CCS and K-wire.

Figure 5

Case 1: postoperative radiograph shows a good reduction position.

Figure 6

Case 1: radiograph 4 months after the operation shows bone union.

2.2. Case 2

A 29-year-old woman fell and injured herself whilst walking down the stairs. She was also diagnosed with a coronoid process fracture, Regan-Morrey type 2. We performed arthroscopic osteosynthesis 5 days after the injury in almost the same way as described in Case 1, using two 3.5 mm CCSs (Figure 7). Postoperatively, she also had a good clinical course; she had no pain and had full range of motion of the elbow joint 1 year after surgery.
Figure 7

Case 2: postoperative radiograph shows fixation by two CCSs.

2.3. Case 3

A 40-year-old man fell and injured himself whilst walking. He was also diagnosed with a coronoid process fracture, Regan-Morrey type 2 (Figure 8). We performed arthroscopic osteosynthesis 10 days after the injury in almost the same way as described in Case 1. However, the fracture was too comminuted to be fixed by CCS, so we performed osteosynthesis using three K-wires (Figure 9). Postoperatively, he wore an immobilizing splint for 2 weeks and then began physical therapy to improve the elbow range of motion. After 4 months, bone union was confirmed, and after 8 months, the K-wires were removed (Figure 10). A follow-up at 10 months showed that he had no pain, and a physical examination revealed complete range of motion, indicating a good clinical course.
Figure 8

Case 3: radiograph demonstrates a type 2 coronoid fracture.

Figure 9

Case 3: postoperative radiograph shows fixation by three K-wires.

Figure 10

Case 3: radiograph 8 months after the operation shows bone union and removal of the K-wire.

3. Discussion

The ulna coronoid process is of critical importance to elbow stability, and strong internal fixation is required for this fracture type [2, 3]. It is generally agreed that Regan-Morrey type 1 fractures are recommended with a nonoperative treatment, whereas type 3 fractures are recognized to require osteosynthesis to avoid recurrent elbow instability [2]. However, opinions are divided on the treatment policy for type 2 fractures [2, 4–9]. Many open methods employing K-wires, screws, soft wires, mini plates, sutures, and others have been described [10-14]. However, these methods require surgery close to the neurovascular bundle; it is quite invasive as the fracture extends deep into the tissue, making it difficult to secure a visual field. Therefore, there are concerns about the occurrence of neurovascular injury, postoperative pain, contracture due to large soft tissue invasion, and insufficient reduction and internal fixation due to the poor visual field. In accordance with the progress of arthroscopic techniques, arthroscopic osteosynthesis for coronoid fractures has been described [14-18]. In arthroscopic osteosynthesis, we can avoid an extensive surgical approach and reach the lesion directly. Therefore, soft tissue invasion is minimal and we can confirm deep layer lesions in detail using the arthroscope monitor. Another advantage of arthroscopic osteosynthesis is that the method of fixing with CCS from the posterior ulnar shaft is simple and it provides a strong fixation. We have successfully performed arthroscopic osteosynthesis in three patients, all of which had good clinical results. In Case 3, we were unable to use CCS, so we performed internal fixation only using K-wires. However, it still had a good clinical result, as in Case 1 and Case 2. We think our method is simple and able to get successful result.

4. Conclusion

Arthroscopic osteosynthesis for ulna coronoid fractures is minimally invasive and is considered to be advantageous for postoperative pain and early recovery.
  17 in total

Review 1.  The unstable elbow.

Authors:  S W O'Driscoll; J B Jupiter; G J King; R N Hotchkiss; B F Morrey
Journal:  Instr Course Lect       Date:  2001

Review 2.  Management of complex elbow instability.

Authors:  Giuseppe Giannicola; Federico Maria Sacchetti; Alessandro Greco; Gianluca Cinotti; Franco Postacchini
Journal:  Musculoskelet Surg       Date:  2010-05

3.  Anterior approach for operative fixation of coronoid fractures in complex elbow instability.

Authors:  Lee M Reichel; Graham S Milam; Charles A Reitman
Journal:  Tech Hand Up Extrem Surg       Date:  2012-06

4.  An original internal fixation technique by tension band wiring with steel wire in fractures of the coronoid process.

Authors:  F Mallard; L Hubert; V Steiger; P Cronier
Journal:  Orthop Traumatol Surg Res       Date:  2015-04-15       Impact factor: 2.256

5.  Coronoid fracture height in terrible-triad injuries.

Authors:  Job N Doornberg; Joppe van Duijn; David Ring
Journal:  J Hand Surg Am       Date:  2006 May-Jun       Impact factor: 2.230

6.  Treatment of the coronoid process fractures with anteromedial approach: a case report.

Authors:  Hongwei Chen; Ziyang Wang; Jun Li; Biao Zhong; Xieyuan Jiang
Journal:  Int J Clin Exp Med       Date:  2015-10-15

7.  Arthroscopic-assisted treatment of coronoid fractures.

Authors:  Julie E Adams; Sheri M Merten; Scott P Steinmann
Journal:  Arthroscopy       Date:  2007-10       Impact factor: 4.772

8.  Soft tissue attachments of the ulnar coronoid process. An anatomic study with radiographic correlation.

Authors:  D J Cage; R A Abrams; J J Callahan; M J Botte
Journal:  Clin Orthop Relat Res       Date:  1995-11       Impact factor: 4.176

Review 9.  [Arthroscopic treatment of acute elbow fractures].

Authors:  N Graveleau; T Bauer; P Hardy
Journal:  Chir Main       Date:  2006-11

10.  Arthroscopic reduction and fixation of coronoid fractures with an exchange rod-a new technique.

Authors:  Kan Ouyang; Daping Wang; Wei Lu; Jianyi Xiong; Jian Xu; Liangquan Peng; Haifeng Liu; Hao Li; Wenzhe Feng
Journal:  J Orthop Surg Res       Date:  2017-01-18       Impact factor: 2.359

View more
  1 in total

1.  Arthroscopic Reduction and Fixation of Coronoid Fractures with Bending K-Wire: A New Technique.

Authors:  Chang Hyun Choi; Hyun-Gyu Seok; Sam-Guk Park
Journal:  J Clin Med       Date:  2022-08-24       Impact factor: 4.964

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.