Literature DB >> 30006862

A randomised trial to compare the increase in intracranial pressure as correlated with the optic nerve sheath diameter during propofol versus sevoflurane-maintained anesthesia in robot-assisted laparoscopic pelvic surgery.

Nambiath Sujata1, Raj Tobin2, Ashwin Tamhankar3, Gagan Gautam3, Abdul Hamid Yatoo2.   

Abstract

Robot-assisted surgery can cause raised intracranial pressures (ICP) due to steep trendelenburg position and pneumoperitoneum. The choice of anesthetic agents can influence the ICP, which can be measured indirectly by correlating it with the sonographically measured optic nerve sheath diameter (ONSD). In this study, our primary aim was to compare the change from baseline of the ONSD during propofol versus sevoflurane-maintained anesthesia in patients undergoing robotic pelvic surgery. In this prospective, interventional, double-blinded study, we randomised 50 patients into two groups P and S. Subjects in group P received intravenous propofol infusion while those in group S received inhalation sevoflurane for maintenance of anesthesia. The ONSD at fixed intervals was noted as the mean of four values measured using ultrasound in both eyes by two independent anesthesiologists who were blinded to the group allocation. The patient demographics and baseline parameters were similar. The mean maximum rise in ONSD from baseline was 0.01 ± 0.01 cm in group P while it was 0.03 ± 0.01 cm in group S (p = 0.001). Percentage change from baseline in group P was 3.41 ± 1.81% and 8.00 ± 2.95% in group S (p = 0.001). We found a positive correlation between the duration of surgery and the maximum rise in ONSD in group S (p = 0.003), but not in group P. Propofol-based total intravenous anesthesia is more effective than inhalation sevoflurane in attenuating the increase in ICP as correlated with the ONSD during robotic pelvic surgery.Clinical trial registration: Yes; Principal investigator: Nambiath Sujata; Trial number: REF/2016/11/012713 (registered); Trial registry: CTRI- http://ctri.nic.in .

Entities:  

Keywords:  Anesthesia agent; Intracranial pressure; Optic nerve sheath diameter; Robotic surgery

Mesh:

Substances:

Year:  2018        PMID: 30006862     DOI: 10.1007/s11701-018-0849-7

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  4 in total

Review 1.  Influence of steep Trendelenburg position on postoperative complications: a systematic review and meta-analysis.

Authors:  Satoshi Katayama; Keiichiro Mori; Benjamin Pradere; Takafumi Yanagisawa; Hadi Mostafaei; Fahad Quhal; Reza Sari Motlagh; Ekaterina Laukhtina; Nico C Grossmann; Pawel Rajwa; Abdulmajeed Aydh; Frederik König; Pierre I Karakiewicz; Motoo Araki; Yasutomo Nasu; Shahrokh F Shariat
Journal:  J Robot Surg       Date:  2021-12-31

2.  Effects of prone positioning with neck extension on intracranial pressure according to optic nerve sheath diameter measured using ultrasound in children.

Authors:  Soo-Bin Yoon; Sang-Hwan Ji; Young-Eun Jang; Ji-Hyun Lee; Eun-Hee Kim; Jin-Tae Kim; Hee-Soo Kim
Journal:  Childs Nerv Syst       Date:  2019-12-04       Impact factor: 1.475

3.  Comparison of the Effects of Propofol and Sevoflurane Anesthesia on Optic Nerve Sheath Diameter in Robot-Assisted Laparoscopic Gynecology Surgery: A Randomized Controlled Trial.

Authors:  Jung Eun Kim; Seong Yoon Koh; In-Jung Jun
Journal:  J Clin Med       Date:  2022-04-12       Impact factor: 4.964

4.  Technical advancements in robotic prostatectomy: single-port extraperitoneal robotic-assisted radical prostatectomy and single-port transperineal robotic-assisted radical prostatectomy.

Authors:  Alireza Aminsharifi; Guilherme Sawczyn; Clark A Wilson; Juan Garisto; Jihad Kaouk
Journal:  Transl Androl Urol       Date:  2020-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.