Literature DB >> 30006685

Factors influencing the effective dose associated with CBCT: a systematic review.

Wilana da Silva Moura1,2, Kelly Chiqueto3,4, Gustavo Menezes Pithon3,5, Leniana Santos Neves3,6, Renata Castro3, José Fernando Castanha Henriques7.   

Abstract

INTRODUCTION: Due to potential impact of the effects of ionizing radiation used in medical and dental examinations on public health in recent years, many studies are being conducted to quantify the radiation dose values, evaluate scanners, and indicate factors that could influence or reduce radiation doses.
OBJECTIVES: This study aimed to evaluate, by a systematic review, the factors that influence the effective radiation dose associated with cone beam computed tomography and respective effects, and compared the effective dose of different cone beam computed tomography (CBCT) scanners with similar exposure parameters.
MATERIALS AND METHODS: A search was conducted on five databases from 2007 to 2015.
RESULTS: The search identified 741 abstracts, among which 44 eligible articles were retrieved in full text. Twenty-three studies met the inclusion criteria and were included. Additional copper filter was evaluated in one study, patient size in 2 studies, region of interest in 1 study, use of a thyroid shield in 2 studies, scan angle in 3 studies, exposure time in 10 studies, FOV diameter in 17 studies, FOV height in 17 studies, kV in 16 studies, mA in 18 studies, mAs in 13 studies, voxel in 8 studies, and resolution in 3 studies. When similar exposure parameters were evaluated, it was observed that CBCT scanner with lower effective dose was Kodak® 9000C 3D (mean 21.2 μSv) in selected studies.
CONCLUSIONS: Thirteen factors were related to changes in the effective dose emitted by different scanners. More studies are needed to identify the image quality requirements in addition to measure the radiation. CLINICAL RELEVANCE: Studies that give more information for professionals who request and interpret the exams and for technicians who perform 3D images about effective radiation dose associated with CBCT are necessary.

Entities:  

Keywords:  Radiation dosage; Radiation exposure measurement; Tomography

Year:  2018        PMID: 30006685     DOI: 10.1007/s00784-018-2561-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  4 in total

Review 1.  Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence.

Authors:  Hugo Gaêta-Araujo; André Ferreira Leite; Karla de Faria Vasconcelos; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2021-02-15       Impact factor: 2.419

Review 2.  A review of dental cone-beam CT dose conversion coefficients.

Authors:  Eugene Mah; E Russell Ritenour; Hai Yao
Journal:  Dentomaxillofac Radiol       Date:  2020-11-11       Impact factor: 2.419

Review 3.  A meta-review of effective doses in dental and maxillofacial cone beam CT using the ROBIS tool.

Authors:  Ayman Al-Okshi; Keith Horner; Madeleine Rohlin
Journal:  Br J Radiol       Date:  2021-05-27       Impact factor: 3.629

4.  Effectiveness of 2D radiographs in detecting CBCT-based incidental findings in orthodontic patients.

Authors:  Jin-Young Choi; Song Hee Oh; Seong-Hun Kim; Hyo-Won Ahn; Yoon-Goo Kang; Yong-Suk Choi; Yoon-Ah Kook; Gerald Nelson
Journal:  Sci Rep       Date:  2021-04-29       Impact factor: 4.379

  4 in total