Literature DB >> 30006223

Effects of modifying implant screw access channels on the amount of extruded excess cement and retention of cement-retained implant-supported dental prostheses: A systematic review.

Amin Davoudi1, Mansour Rismanchian2.   

Abstract

STATEMENT OF PROBLEM: Cement-retained implant-supported prostheses eliminate screw loosening and enhance esthetics. However, retrievability and the possibility of removing extruded excess cement (EEC) have been problematic.
PURPOSE: The purpose of this systematic review was to analyze the effects of modifying the screw access channel (SAC) on the amount of EEC and the retention of cement-retained implant-supported prostheses.
MATERIAL AND METHODS: PubMed, Web of Science, Scopus, and Google Scholar databases were searched with appropriate key words. Related titles and abstracts published up to June 2017 were screened and selected on the basis of defined inclusion criteria. Full texts of all studies were read and subjected to quality assessments. After the initial search, 1521 articles were included in the study. Of these, 11 studies were subjected to critical appraisal, and 10 of them were reliable enough in methodology to be systemically reviewed.
RESULTS: All the studies were in vitro and described a total of 260 specimens. According to the interpreted results, closed SACs caused lower retention with a higher amount of EEC, whereas open SACs caused the reverse. Also, as the abutment height decreased, retention decreased.
CONCLUSIONS: Extending the crown's margin into the SAC, leaving the SAC open, and using internal vents in the SAC space are possible methods of modifying the SAC to gain higher retentive values. Also, the use of internal vents in the SAC system and open or partially filled SAC space reduce the amount of EEC.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2018        PMID: 30006223     DOI: 10.1016/j.prosdent.2018.03.002

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Assessment of Preload Loss after Cyclic Loading in the OT Bridge System in an "All-on-Four" Rehabilitation Model in the Absence of One and Two Prosthesis Screws.

Authors:  Mario Cesare Pozzan; Francesco Grande; Edoardo Mochi Zamperoli; Fabio Tesini; Massimo Carossa; Santo Catapano
Journal:  Materials (Basel)       Date:  2022-02-20       Impact factor: 3.623

2.  Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China.

Authors:  Cai Wen; Rong Jiang; Zhiqiang Zhang; Bo Lei; Yingquan Zhong; Huangjun Zhou
Journal:  Patient Prefer Adherence       Date:  2022-02-17       Impact factor: 2.711

3.  The effect of different cleansing methods for removing temporary cement on the tensile bond force of permanently cemented implant-supported metal copings: An in vitro study.

Authors:  Behnaz Ebadian; Mohammad Jowkar; Amin Davoudi; Amirhossein Fathi; Mohsen Ziaei; Einar Berg
Journal:  Clin Exp Dent Res       Date:  2022-05-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.