Literature DB >> 3000496

Silicone-implant replacement arthroplasty in fractures of the radial head. A follow-up report.

B Martinelli.   

Abstract

A follow-up of the results of silicone replacement arthroplasty in radial head fractures in 51 patients after 3-11 years is presented. Although the clinical picture remained unchanged, radiographs revealed varying degrees of wear on the implants, down to complete fragmentation. The author concludes that silicone implants are well tolerated but not sufficiently resistant to wear.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3000496

Source DB:  PubMed          Journal:  Bull Hosp Jt Dis Orthop Inst        ISSN: 0883-9344


  2 in total

1.  Absorbable polyglycolide pins in fixation of displaced fractures of the radial head.

Authors:  E Hirvensalo; O Böstman; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

Review 2.  [Resection of the radius head in multiple and comminuted fractures. Clinical results and critical evaluation compared with the literature].

Authors:  J V Wening; B Wobig; K H Jungbluth
Journal:  Unfallchirurgie       Date:  1993-06
  2 in total