| Literature DB >> 30003058 |
Mirella Lemos Queiróz Tavares1, Carlos Nelson Elias2, Lincoln Issamu Nojima1.
Abstract
OBJECTIVE: We aimed to perform in-vitro evaluation to compare 1) shear bond strength (SBS), adhesive remnant index (ARI), and color change between self-etched and acid-etched primers; 2) the SBS, ARI and color change between direct and indirect bonding; and 3) the enamel roughness (ER) between 12-blade bur and aluminum oxide polisher debonding methods.Entities:
Keywords: Bonding; Color change; Enamel roughness; Shear strength
Year: 2018 PMID: 30003058 PMCID: PMC6041458 DOI: 10.4041/kjod.2018.48.4.245
Source DB: PubMed Journal: Korean J Orthod Impact factor: 1.372
Distribution of the groups according to the method used for brackets bonding, the adhesive system used, and the adhesive removal method
Control, No bonding was performed; DTBX, Transbond XT Primer and Adhesive (3M Unitek, Monrovia, CA, USA) were used to direct bonding, and 12-blade bur at low speed to remove the adhesive remnant; ITBX, Transbond XT Primer and Adhesive (3M Unitek) were used to indirect bonding, and 12-blade bur at low speed to remove the adhesive remnant; IZ350, Transbond XT Primer and Z350 flow resin (3M Unitek) were used to indirect bonding, and 12-blade bur at low speed to remove the adhesive remnant; ISONDHI, Sondhi Rapid-set and Transbond XT Adhesive (3M Unitek) were used to indirect bonding, and 12-blade bur at low speed to remove the adhesive remnant; ISEP, Transbond Plus Self-Etching Primer (SEP, 3M Unitek) and Transbond XT Adhesive (3M Unitek) were used to indirect bonding, and 12-blade bur at low speed to remove the adhesive remnant; ITBXp, Transbond XT Primer and Adhesive (3M Unitek) were used to indirect bonding, and polisher of aluminum oxide at low speed to remove the adhesive remnant.
The shear bond strengths (MPa)
SD, Standard deviation.
ANOVA and Tukey's post-hoc test were performed.
A,B,CSame letters indicate no statistically significant difference among groups (p > 0.05).
For the definition of each group, see the footnote in Table 1.
Number of subjects for each adhesive remnant index (ARI)
The Kruskal-Wallis test showed that there were no statistically significant difference among the 5 groups (p > 0.05).
For the definition of each group, see the footnote in Table 1.
Roughness parameter analyses according to the paired t-test
ITBX, Transbond XT Primer and Adhesive with 12-blade bur were used; ITBXp, Transbond XT Primer and Adhesive with polisher of aluminum oxide were used; SD, standard deviation; Ra, medium roughness; Rz, medium depth roughness.
*Statistically significant differences between initial and final values (p < 0.05).
Figure 1A, Three-dimensional (3D) profile of ITBX before bonding. B, 3D profile of ITBX after clean-up. C, 3D profile of IBTXp before bonding. D, 3D profile of ITBXp after clean-up. Red represents the peak, and blue, the valley.
Comparisons of ΔRa and ΔRz for ITBX and ITBXp groups
Values are presented as mean ± standard deviation.
Independent t-tests were performed.
ITBX, Transbond XT Primer and Adhesive with 12-blade bur were used; ITBXp, Transbond XT Primer and Adhesive with polisher of aluminum oxide were used; Ra, medium roughness; Rz, medium depth roughness.
Color changes (ΔE values) before bonding and after clean-up
SD, Standard deviation.
ANOVA and Tukey's post-hoc test were performed.
There was no statistically significant difference among groups (p > 0.05).
For the definition of each group, see the footnote in Table 1.