Literature DB >> 29997192

Hemodynamic assessments of venous pulsatile tinnitus using 4D-flow MRI.

Yunduo Li1, Huijun Chen1, Le He1, Xiangyu Cao1, Xianling Wang1, Shubin Chen1, Rui Li2, Chun Yuan1.   

Abstract

OBJECTIVE: To use 4D-flow MRI to characterize hemodynamics of transverse and sigmoid sinus in venous pulsatile tinnitus (PT) patients and to investigate their differences vs healthy controls.
METHODS: A total of 21 patients with venous PT and 11 healthy controls were included in the retrospective study. All participants underwent 4D-flow and magnetic resonance venography scan in a 3.0T magnetic resonance scanner. All visualization, quantification, and analysis of 4D-flow data were performed using dedicated software. Two independent reviewers evaluated the existence of vortex or turbulence. Covariance analysis adjusted for age was used to compare average through-plane velocity (Vtp_avg), maximum through-plane velocity (Vtp_max), average velocity (Vavg), maximum velocity (Vmax), average blood flow (Flowavg), and pulsatility index (PI) between PT and control group.
RESULTS: There were hemodynamic differences between PT patients and healthy controls. Compared with the control group, the PT group showed significantly higher Vtp_avg, Vtp_max, Vavg, Vmax, and Flowavg, and slightly higher PI. For the assessment of flow pattern, inter-reader reproducibility was excellent (κ = 1.00). Vortex or turbulence was observed in PT patients with good sensitivity (86.4%) and specificity (90.9%). Drainage dominance was more frequently observed in patients (15/21, 71.4%) than healthy controls (4/11, 36.4%).
CONCLUSIONS: Significant hemodynamic differences were found between venous PT patients and healthy controls with 4D-flow MRI. Hemodynamic conditions could serve as noninvasive biomarkers for diagnosis and treatment evaluation of venous PT. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that 4D-flow MRI accurately identifies patients with venous PT.
© 2018 American Academy of Neurology.

Entities:  

Mesh:

Year:  2018        PMID: 29997192     DOI: 10.1212/WNL.0000000000005948

Source DB:  PubMed          Journal:  Neurology        ISSN: 0028-3878            Impact factor:   9.910


  8 in total

1.  Blood flow and perfusion lateralization in border zone infarct using 4D flow and arterial spin labeling.

Authors:  Wenwen Chen; Xiaowei Song; Shuo Chen; Zhensen Chen; Mingzhu Fu; Chenming Wei; Zhuozhao Zheng; Jian Wu; Rui Li
Journal:  Neuroradiology       Date:  2022-05-30       Impact factor: 2.995

2.  Associations between morphology and hemodynamics of intracranial aneurysms based on 4D flow and black-blood magnetic resonance imaging.

Authors:  Miaoqi Zhang; Fei Peng; Yunduo Li; Le He; Aihua Liu; Rui Li
Journal:  Quant Imaging Med Surg       Date:  2021-02

3.  Bone remodeling in sigmoid sinus diverticulum after stenting for transverse sinus stenosis in pulsatile tinnitus: A case report.

Authors:  Xiao-Yu Qiu; Peng-Fei Zhao; He-Yu Ding; Xiao-Shuai Li; Han Lv; Zheng-Han Yang; Shu-Sheng Gong; Long Jin; Zhen-Chang Wang
Journal:  World J Clin Cases       Date:  2021-04-06       Impact factor: 1.337

4.  The Relationships Among Transverse Sinus Stenosis Measured by CT Venography, Venous Trans-stenotic Pressure Gradient and Intracranial Pressure in Patients With Unilateral Venous Pulsatile Tinnitus.

Authors:  Xiaoyu Qiu; Pengfei Zhao; Xiaoshuai Li; Heyu Ding; Han Lv; Rong Zeng; Guopeng Wang; Long Jin; Zhenghan Yang; Shusheng Gong; Zhenchang Wang
Journal:  Front Neurosci       Date:  2021-09-03       Impact factor: 4.677

5.  Daily blood pressure profile and blood-brain barrier permeability in patients with cerebral small vessel disease.

Authors:  L A Dobrynina; K V Shamtieva; E I Kremneva; M R Zabitova; B M Akhmetzyanov; E V Gnedovskaya; M V Krotenkova
Journal:  Sci Rep       Date:  2022-05-11       Impact factor: 4.996

6.  Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications.

Authors:  Maria Aristova; Jianing Pang; Yue Ma; Liliana Ma; Haben Berhane; Vitaliy Rayz; Michael Markl; Susanne Schnell
Journal:  Magn Reson Med       Date:  2022-06-26       Impact factor: 3.737

7.  Intracranial pressure, lateral sinus patency, and jugular ultrasound hemodynamics in patients with venous pulsatile tinnitus.

Authors:  Xiuli Gao; Yue-Lin Hsieh; Shenjiang Wang; Suming Shi; Wuqing Wang
Journal:  Front Neurol       Date:  2022-09-16       Impact factor: 4.086

8.  The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study.

Authors:  Zhaohui Liu; Wenjuan Liu; Xueying He; Baowei Li; Lirong Zhang
Journal:  J Int Adv Otol       Date:  2021-07       Impact factor: 1.017

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.