Literature DB >> 29994203

Development of Dual-Frequency Oblong-Shaped-Focused Transducers for Intravascular Ultrasound Tissue Harmonic Imaging.

Junsu Lee, Eui-Ji Shin, Changyang Lee, Jin Ho Chang.   

Abstract

Tissue harmonic imaging (THI), an essential mode of commercial ultrasound imaging scanners, can provide images with high spatial and contrast resolutions. For THI, the frequency spectrum of a transducer is generally divided for the transmission of fundamental signal and the reception of its second harmonic. Therefore, it is difficult to use the THI mode for intravascular ultrasound (IVUS) imaging because typical IVUS transducers have a narrow -6-dB fractional bandwidth of about 50%. Due to its small aperture (about 0.5 mm) and the strength of IVUS being too weak, it is difficult to construct a high-quality tissue harmonic image. In this paper, we report a recently developed dual-frequency oblong-shaped-focused IVUS transducer for high-quality intravascular THI; the transducer consists of three elements arranged side by side in the horizontal (i.e., elevation) direction. The two outer elements with a center frequency of 35 MHz are responsible for ultrasound transmission and the center element has a center frequency of 70 MHz for the reception of the second-harmonic signals. All three elements have a spherical shape with a radius of 3 mm to efficiently generate harmonics in the region of interest. This configuration of the developed IVUS transducer was determined to facilitate high-quality THI, which was based on the results of Field II simulation and finite-element analysis. The images of wires and a tissue-mimicking phantom indicated that the tissue harmonic images produced by the developed transducer have not only a high spatial resolution but also a deep imaging depth, compared to the 35- and 70-MHz fundamental images.

Entities:  

Mesh:

Year:  2018        PMID: 29994203     DOI: 10.1109/TUFFC.2018.2844869

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  A 40-MHz Ultrasound Transducer with an Angled Aperture for Guiding Percutaneous Revascularization of Chronic Total Occlusion: A Feasibility Study.

Authors:  Junsu Lee; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2018-11-21       Impact factor: 3.576

Review 2.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

Review 3.  Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review.

Authors:  Jin-Ho Sung; Jin-Ho Chang
Journal:  Sensors (Basel)       Date:  2021-06-05       Impact factor: 3.576

4.  A 35 MHz/105 MHz Dual-Element Focused Transducer for Intravascular Ultrasound Tissue Imaging Using the Third Harmonic.

Authors:  Junsu Lee; Ju-Young Moon; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2018-07-15       Impact factor: 3.576

5.  A Single-Chip High-Voltage Integrated Actuator for Biomedical Ultrasound Scanners.

Authors:  Chin Hsia; Yi-Chi Hsiao; Yen-Chung Huang
Journal:  Sensors (Basel)       Date:  2019-11-20       Impact factor: 3.576

  5 in total