Literature DB >> 29993368

Signal Coherence and Image Amplitude With the Filtered Delay Multiply and Sum Beamformer.

Fabrice Prieur, Ole Marius Hoel Rindal, Andreas Austeng.   

Abstract

The filtered delay multiply and sum (F-DMAS) beamformer has recently been presented in the context of medical ultrasound image formation. This nonlinear beamformer produces images with improved contrast resolution and noise rejection when compared with the delay and sum (DAS) beamformer. In an attempt to better understand the origin of the improved image quality, this paper shows a theoretical study of the image amplitude statistics backed up by numerical simulations. The results show that the difference in image amplitude using the DAS or F-DMAS beamformers can be partly explained by the way signal coherence influences both beamformers. When using the F-DMAS compared with the DAS beamformer, the image amplitude is shown to be more dependent on the signal coherence. Experimental ultrasound images of a phantom confirm our findings.

Mesh:

Year:  2018        PMID: 29993368     DOI: 10.1109/TUFFC.2018.2831789

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  8 in total

1.  Speckle coherence of piecewise-stationary stochastic targets.

Authors:  Matthew R Morgan; Gregg E Trahey; William F Walker
Journal:  J Acoust Soc Am       Date:  2019-09       Impact factor: 1.840

2.  Synthetic Aperture Focusing for Multi-Covariate Imaging of Sub-Resolution Targets.

Authors:  Matthew R Morgan; Nick Bottenus; Gregg E Trahey; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-01-13       Impact factor: 2.725

3.  Multi-covariate Imaging of Sub-resolution Targets.

Authors:  Matthew R Morgan; Gregg E Trahey; William F Walker
Journal:  IEEE Trans Med Imaging       Date:  2019-05-15       Impact factor: 10.048

4.  Incoherent Clutter Suppression Using Lag-One Coherence.

Authors:  Will Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-02-28       Impact factor: 2.725

5.  Lag-Based Filtered-Delay Multiply and Sum Beamformer Combined with Two Phase-Related Factors for Medical Ultrasound Imaging.

Authors:  Ke Song; Paul Liu; Dong C Liu
Journal:  Comput Math Methods Med       Date:  2020-08-28       Impact factor: 2.238

Review 6.  Nonlinear mechanisms in photoacoustics-Powerful tools in photoacoustic imaging.

Authors:  Rongkang Gao; Zhiqiang Xu; Yaguang Ren; Liang Song; Chengbo Liu
Journal:  Photoacoustics       Date:  2021-02-01

Review 7.  Advances in ultrasonography: image formation and quality assessment.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

8.  Optimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systems.

Authors:  Anudeep Vayyeti; Arun K Thittai
Journal:  Sci Rep       Date:  2021-11-03       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.