Literature DB >> 29993238

Integrated Antibody with Catalytic Metal-Organic Framework for Colorimetric Immunoassay.

Caihong Wang1, Jie Gao1, Hongliang Tan1.   

Abstract

Enzyme-linked immunosorbent assay has been widely used as a gold standard in biomedical field, but some inevitable drawbacks still exist in its practical applications, especially the laborious preparation of enzyme-antibody conjugates by a covalent linkage. In this work, we proposed a new strategy to prepare enzyme-antibody conjugate by integrating antibody with catalytic metal-organic framework (MOF) to form dual-functional MOF/antibody composite. As models, rabbit antimouse immunoglobulin G antibody (RIgG) and Cu-MOF with peroxidase-like activity were used to fabricate RIgG@Cu-MOF composite for colorimetric immunoassay. It was found that Cu-MOF as a host not only has no influence on the original capture ability of RIgG to its corresponding antigen (mIgG), but also can shield RIgG against long-term storage, high temperature, and biological degradation. More importantly, upon the formation of sandwiched immunocomplex between RIgG@Cu-MOF and capture antibody, Cu-MOF can serve as a signal amplification unit to perform colorimetric immunoassay. The detection limit of RIgG@Cu-MOF toward mIgG was obtained at 0.34 ng/mL, which is 3-fold lower than that of horseradish peroxidase labeled RIgG. Furthermore, the successful determination of mIgG in serum sample demonstrates the applicability of RIgG@Cu-MOF in detecting real sample. Therefore, it is highly anticipated that this study can offer a new way to prepare enzyme-antibody conjugates, facilitating the exploration of MOF composites in biomedical field.

Entities:  

Keywords:  ELISA; IgG; MOF composite; colorimetric immunoassay; peroxidase mimic

Mesh:

Substances:

Year:  2018        PMID: 29993238     DOI: 10.1021/acsami.8b07225

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  7 in total

1.  Colorimetric biosensor for visual determination of Golgi protein 73 based on reduced graphene oxide-carboxymethyl chitosan-Hemin/platinum@palladium nanozyme with peroxidase-like activity.

Authors:  Xinhao Li; Shengnan Li; Qiuyan Lv; Chaoxian Wang; Jintao Liang; Zhide Zhou; Guiyin Li
Journal:  Mikrochim Acta       Date:  2022-09-23       Impact factor: 6.408

Review 2.  Two-Dimensional Material-Based Colorimetric Biosensors: A Review.

Authors:  Danzhu Zhu; Bin Liu; Gang Wei
Journal:  Biosensors (Basel)       Date:  2021-07-31

Review 3.  Metal-Organic Frameworks-Based Sensors for Food Safety.

Authors:  Aloys Hitabatuma; Peilong Wang; Xiaoou Su; Mengmeng Ma
Journal:  Foods       Date:  2022-01-28

4.  Adenosine triphosphate-activated prodrug system for on-demand bacterial inactivation and wound disinfection.

Authors:  Yuhao Weng; Huihong Chen; Xiaoqian Chen; Huilin Yang; Chia-Hung Chen; Hongliang Tan
Journal:  Nat Commun       Date:  2022-08-11       Impact factor: 17.694

Review 5.  An overview on the investigation of nanomaterials' effect on plasma components: immunoglobulins and coagulation factor VIII, 2010-2020 review.

Authors:  Tahereh Zadeh Mehrizi; Kamran Mousavi Hosseini
Journal:  Nanoscale Adv       Date:  2021-05-18

Review 6.  Metal-organic frameworks for virus detection.

Authors:  Ying Wang; Yaqin Hu; Qunye He; Jianhua Yan; Hongjie Xiong; Nachuan Wen; Shundong Cai; Dongming Peng; Yanfei Liu; Zhenbao Liu
Journal:  Biosens Bioelectron       Date:  2020-09-14       Impact factor: 10.618

Review 7.  Explaining chemical clues of metal organic framework-nanozyme nano-/micro-motors in targeted treatment of cancers: benchmarks and challenges.

Authors:  Mojtaba Falahati; Majid Sharifi; Timo L M Ten Hagen
Journal:  J Nanobiotechnology       Date:  2022-03-24       Impact factor: 10.435

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.