Literature DB >> 29990643

Application of an optimal class of antisymmetric wavelet filter banks for obstructive sleep apnea diagnosis using ECG signals.

Manish Sharma1, Shreyansh Agarwal2, U Rajendra Acharya3.   

Abstract

Obstructive sleep apnea (OSA) is a sleep disorder caused due to interruption of breathing resulting in insufficient oxygen to the human body and brain. If the OSA is detected and treated at an early stage the possibility of severe health impairment can be mitigated. Therefore, an accurate automated OSA detection system is indispensable. Generally, OSA based computer-aided diagnosis (CAD) system employs multi-channel, multi-signal physiological signals. However, there is a great need for single-channel bio-signal based low-power, a portable OSA-CAD system which can be used at home. In this study, we propose single-channel electrocardiogram (ECG) based OSA-CAD system using a new class of optimal biorthogonal antisymmetric wavelet filter bank (BAWFB). In this class of filter bank, all filters are of even length. The filter bank design problem is transformed into a constrained optimization problem wherein the objective is to minimize either frequency-spread for the given time-spread or time-spread for the given frequency-spread. The optimization problem is formulated as a semi-definite programming (SDP) problem. In the SDP problem, the objective function (time-spread or frequency-spread), constraints of perfect reconstruction (PR) and zero moment (ZM) are incorporated in their time domain matrix formulations. The global solution for SDP is obtained using interior point algorithm. The newly designed BAWFB is used for the classification of OSA using ECG signals taken from the physionet's Apnea-ECG database. The ECG segments of 1 min duration are decomposed into six wavelet subbands (WSBs) by employing the proposed BAWFB. Then, the fuzzy entropy (FE) and log-energy (LE) features are computed from all six WSBs. The FE and LE features are classified into normal and OSA groups using least squares support vector machine (LS-SVM) with 35-fold cross-validation strategy. The proposed OSA detection model achieved the average classification accuracy, sensitivity, specificity and F-score of 90.11%, 90.87% 88.88% and 0.92, respectively. The performance of the model is found to be better than the existing works in detecting OSA using the same database. Thus, the proposed automated OSA detection system is accurate, cost-effective and ready to be tested with a huge database.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Apnea; Classification; ECG; Filter design; Obstructive sleep apnea; Optimization; Wavelets

Mesh:

Year:  2018        PMID: 29990643     DOI: 10.1016/j.compbiomed.2018.06.011

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  8 in total

1.  Application of the Variance Delay Fuzzy Approximate Entropy for Autonomic Nervous System Fluctuation Analysis in Obstructive Sleep Apnea Patients.

Authors:  Yifan Li; Shan Wu; Quanan Yang; Guanzheng Liu; Leijiao Ge
Journal:  Entropy (Basel)       Date:  2020-08-21       Impact factor: 2.524

Review 2.  Automated Detection of Hypertension Using Physiological Signals: A Review.

Authors:  Manish Sharma; Jaypal Singh Rajput; Ru San Tan; U Rajendra Acharya
Journal:  Int J Environ Res Public Health       Date:  2021-05-29       Impact factor: 3.390

3.  Automated detection of schizophrenia using optimal wavelet-based l 1 norm features extracted from single-channel EEG.

Authors:  Manish Sharma; U Rajendra Acharya
Journal:  Cogn Neurodyn       Date:  2021-01-15       Impact factor: 3.473

4.  An automatic EEG-based sleep staging system with introducing NAoSP and NAoGP as new metrics for sleep staging systems.

Authors:  Mesut Melek; Negin Manshouri; Temel Kayikcioglu
Journal:  Cogn Neurodyn       Date:  2020-10-12       Impact factor: 3.473

5.  Hypertension Diagnosis Index for Discrimination of High-Risk Hypertension ECG Signals Using Optimal Orthogonal Wavelet Filter Bank.

Authors:  Jaypal Singh Rajput; Manish Sharma; U Rajendra Acharya
Journal:  Int J Environ Res Public Health       Date:  2019-10-23       Impact factor: 3.390

6.  Automatic Sleep-Stage Scoring in Healthy and Sleep Disorder Patients Using Optimal Wavelet Filter Bank Technique with EEG Signals.

Authors:  Manish Sharma; Jainendra Tiwari; U Rajendra Acharya
Journal:  Int J Environ Res Public Health       Date:  2021-03-17       Impact factor: 3.390

7.  Sleep Apnea Detection Based on Multi-Scale Residual Network.

Authors:  Hengyang Fang; Changhua Lu; Feng Hong; Weiwei Jiang; Tao Wang
Journal:  Life (Basel)       Date:  2022-01-14

8.  Contribution of Different Subbands of ECG in Sleep Apnea Detection Evaluated Using Filter Bank Decomposition and a Convolutional Neural Network.

Authors:  Cheng-Yu Yeh; Hung-Yu Chang; Jiy-Yao Hu; Chun-Cheng Lin
Journal:  Sensors (Basel)       Date:  2022-01-10       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.