| Literature DB >> 29988192 |
Sultana Shahana Banu1,2,3, Be-Nazir Ahmed3, Abul Khair Mohammad Shamsuzzaman3, Rogan Lee1,2.
Abstract
BACKGROUND: Definitive diagnosis of visceral leishmaniasis (VL) by demonstrating parasites in tissue smears or by culture involves invasive procedures, technical expertise and adequate laboratory facilities. Endemic countries rely mainly on serological tests to diagnose VL. Currently, the immunochromatographic test incorporating the recombinant K39 antigen (rK39 ICT) is the reference test for rapid diagnosis of VL in the Indian subcontinent. The performance of serological tests using rK39 and other promastigote antigens can vary due to differences in antigen expression, the various hosts and environmental factors. To achieve elimination of VL, diagnostic accuracy will be necessary for active case detection especially in those who carry asymptomatic infections. We evaluated the performance of rK39 ICT, enzyme linked immunosorbent assay using mixed Leishmania promastigotes from different Leishmania species (p-ELISA) and indirect fluorescent antibody test (IFAT) utilizing whole promastigotes from the Leishmania donovani complex for sero-diagnosis of VL in Bangladesh.Entities:
Keywords: IFAT; Predictive value; Sensitivity; Specificity; Visceral leishmaniasis; p-ELISA; rK39 ICT
Year: 2016 PMID: 29988192 PMCID: PMC5991841 DOI: 10.1016/j.parepi.2016.07.003
Source DB: PubMed Journal: Parasite Epidemiol Control ISSN: 2405-6731
Sensitivity of three serological methods in 155 cases of confirmed VL.
| Serological test | Positive | Sensitivity | 95% CI |
|---|---|---|---|
| n | % | % | |
| rK39 ICT | 155 | 100 | 97.6–100 |
| p-ELISA | 134 | 86.5 | 80.2–91.0 |
| IFAT | 143 | 92.3 | 87.0–95.5 |
| rK39 ICT, p-ELISA & IFAT | 128 | 82.6 | 75.8–87.7 |
CI = Confidence interval.
Specificity and predictive values of three serological methods when tested against control sera or plasma.
| Serological test | Specificity in control groups, % (95% CI | Predictive value (95% CI) | ||||||
|---|---|---|---|---|---|---|---|---|
| Group II (n = 351) | Group III (n = 355) | Group IV (n = 91) | Group V (n = 91) | Group VI (n = 91) | All groups (n = 979) | PPV | NPV | |
| rK39 ICT | 100 (99.9–100) | 100 (98.9–100) | 100 (96–100) | 100 (96–100) | 100 (96–100) | 100 (99.6–100) | 100 (97.6–100) | 100 (99.6–100) |
| p-ELISA | 98.6 (96.7–99.4) | 98.9 (97.1–99.6) | 100 (96–100) | 63.7 (53.5–72.9) | 71.4 (61.4–79.7) | 93.1 (91.3–94.5) | 66.3 (59.6–72.5) | 97.8 (96.6–98.5) |
| IFAT | 99.7 (98.4–100) | 100 (98.9–100) | 100 (96–100) | 100 (96–100) | 100 (96–100) | 99.9 (99.4–100) | 99.3 (96.2–99.9) | 98.8 (97.9–99.3) |
CI = Confidence interval.
PPV = Positive predictive value.
NPV = Negative predictive value.
Comparison of sensitivities and specificities of rK39 ICT kits used in the Indian subcontinent.
| Country | Product | Manufacturer | Sensitivity n (%) (95% CI) | Specificity n (%) (95% CI) | Reference |
|---|---|---|---|---|---|
| India | Kala-azar Detect | InBios International Inc., Seattle, WA | 57 (100) (93.7–100) | 116 (100) (96.8–100) | |
| IT-LEISH | Diamed AG | 221 (99.0–100) (97.5–99.9) | 365 (95–100) | ||
| Onsite | CTK Biotech Inc., San Diego, CA, USA | 145 (96.7) (92.4–98.9) | 112 (94.1) (88.3–97.6) | ||
| Onsite | CTK Biotech Inc., San Diego, CA, USA | 148 (98.7) (95.3–99.8) | 50 (42.0) (33.0–51.4) | ||
| Kala-azar Detect | InBios International Inc., Seattle, WA | 149 (99.3) (96.3–100) | 118 (99.2) (95.4–100) | ||
| Diamed-IT LEISH | Bio-Rad Laboratories | 148 (98.7) (95.3–99.8) | 118 (99.2) (95.4–100) | ||
| Kala-azar Detect | InBios International Inc., Seattle, WA | 365 (100) (98.9–100) | 421 (94–100) (94.5–100) | ||
| Nepal | Onsite | CTK Biotech Inc., San Diego, CA, USA | 26 (96.3) (81.0–99.9) | 137 (90.1) (84.3–94.4) | |
| Onsite | CTK Biotech Inc., San Diego, CA, USA | 27 (100) (87.0–100) | 74 (48.7) (40.5–56.9) | ||
| Kala-azar Detect | InBios International Inc., Seattle, WA | 26 (96.3) (81.0–99.9) | 143 (94.1) (89.1–97.3) | ||
| Diamed-IT LEISH | Bio-Rad Laboratories | 26 (96.3) (81.0–99.9) | 141 (92.8) (87.4–96.3) | ||
| ISC (Bangladesh, India and Nepal) | Diamed-IT LEISH | Bio-Rad Laboratories | 250 (98.8) (96.5–99.6) | 249 (97.6) (94.8–98.9) | |
| Kala-azar Detect | InBios International Inc., Seattle, WA | 250 (99.6) (97.8–99.9) | 249 (96.0) (92.8–97.8) | ||
| Onsite | CTK Biotech Inc. | 250 (99.6) (97.8–99.9) | 249 (96.8) (93.8–98.4) | ||
| Bangladesh | NA | NA | 60 (96.6) (88.6–99.1) | 120 (98.3) (94.1–99.5) | |
| NA | NA | 60 (95) (86.3–98.3) | 60 (98.3) (91.1–99.7) | ||
| SD | Standard Diagnostics, INC. Yongin-si, Gyeonggi-do, Korea | 155 (100) (97.6–100) | 979 (100) (99.6–100) | Current study |
Information not available.