Abstract
The advantages of polychromatic ultraviolet (UV) light for viral disinfection can be optimized for disinfection using emerging tailored wavelength sources including KrCl excimer lamps and light emitting diodes (LEDs). Disinfection of the common viral surrogate MS2 bacteriophage was measured after exposure to these emerging sources and conventional low pressure (LP) mercury UV lamps in individual or sequential exposures. The first dose response for any virus (MS2) exposed to a KrCl excimer lamp is reported, showing the high efficiency of fluence-based disinfection because of increased viral susceptibility at the low wavelengths emitted by the excilamp. Sequential exposure dose responses indicated synergy from sequential exposures of LP and excimer lamps, which were competitive on an electrical basis at worst-and best-case scenarios of wall plug efficiency with current medium pressure (MP) disinfection. Best-case scenarios for electrical efficiency also showed all sequential exposures to be competitive with MP UV disinfection. Predictive models for sequential exposure dose responses were assessed to support the current feasibility of incorporating sequential UV exposures to optimize tailored wavelength viral disinfection.Entities:
Keywords: Disinfection; KrCl excimer lamp; UV-C light emitting diode (LED); Ultraviolet (UV); Virus; Water
Mesh:
Substances:
Year: 2018 PMID: 29986239 DOI: 10.1016/j.watres.2018.06.017
Source DB: PubMed Journal: Water Res ISSN: 0043-1354 Impact factor: 11.236