Literature DB >> 29985528

Fracture incidence of instruments from a single-file reciprocating system by students in an endodontic graduate programme: a cross-sectional retrospective study.

H Caballero-Flores1, C K Nabeshima1, E Binotto1, M E L Machado1.   

Abstract

AIM: To assess the fracture incidence of instruments from single-file reciprocating systems when used by students in an endodontic graduate programme.
METHODOLOGY: Dental records and periapical radiographs of patients treated by students on an endodontic graduate programme using reciprocating systems were assessed. Data on tooth type, number of treated root canals, number of fractured instruments, fragment size, angle, radius, arc length and position of root canal curvature where fractures occurred were tabulated for analysis. The risk of fracture was calculated for each group of teeth, root canal and root thirds, whilst the incidence of fractures reported for the reciprocating systems was compared using the chi-squared test at 5% significance level.
RESULTS: Overall, 2056 root canals (826 teeth) from 810 patients were included. The incidence of fractured files from single-file reciprocating systems in relation to a number of instrumented canals was 0.92%. Fracture rates of 0.84% and 0.93% were found in 830 and 1226 root canals instrumented with WaveOne and Reciproc systems, respectively. No significant differences were observed between the systems. The highest fracture rate was 52.6% in the mesiobuccal root of mandibular molars. The central angle, radius and arc length of the curvature of root canals where the instruments fractured ranged from 58° to 84°, from 1.7 to 7.2 mm and from 2.4 to 7.6 mm, respectively.
CONCLUSION: The use of WaveOne and Reciproc single-file reciprocating systems in an endodontic graduate programme was associated with a low incidence of instrument fractures.
© 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Reciproc; WaveOne; endodontic graduate programme; fracture incidence; reuse

Mesh:

Substances:

Year:  2018        PMID: 29985528     DOI: 10.1111/iej.12982

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  The incidence of nickel-titanium endodontic hand file fractures: A 7-year retrospective study in a tertiary care hospital.

Authors:  Arun Kumar Patnana; Ankita Chugh; Vinay Kumar Chugh; Pravin Kumar
Journal:  J Conserv Dent       Date:  2020-10-10

Review 2.  Techniques to address fractured instruments in the middle or apical third of the root canal in human permanent teeth: a systematic review of the in vitro studies.

Authors:  Nathalia Nadalon Portela; Júlia Petry Rech; Ana Maria Estivalete Marchionatti; Jéssica Copetti Barasuol
Journal:  Clin Oral Investig       Date:  2021-10-26       Impact factor: 3.573

3.  Reciproc Endodontic File Surface Defects After Single Use: An SEM Analysis.

Authors:  Mohammed Howait
Journal:  J Int Soc Prev Community Dent       Date:  2021-01-30

4.  Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study.

Authors:  Liliana Machado Ruivo; Marcos de Azevedo Rios; Alexandre Mascarenhas Villela; Alexandre Sigrist de Martin; Augusto Shoji Kato; Rina Andrea Pelegrine; Ana Flávia Almeida Barbosa; Emmanuel João Nogueira Leal Silva; Carlos Eduardo da Silveira Bueno
Journal:  Restor Dent Endod       Date:  2021-09-09

5.  Incidence of fracture of ProDesign Logic system instruments: A cross-sectional retrospective study.

Authors:  Ricardo Machado; Claudemir de Souza Júnior; Bruna Larissa Mendes; Viviane Vieira; Stella Maria Glaci Reinke; Ana Cristina Gonçalves Kovalik; Eduardo Donato Eing Elgelke Back; Daniel Comparin
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.996

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.