Literature DB >> 29979363

Accuracy of Three Software Applications for Breast Volume Calculations from Three-Dimensional Surface Images.

Tycho S Wesselius1, Arico C Verhulst1, Rinaldo D Vreeken1, Tong Xi1, Thomas J J Maal1, Dietmar J O Ulrich1.   

Abstract

BACKGROUND: Knowing breast volumes before certain surgeries helps the surgeon to obtain breast symmetry. Calculating breast volumes from three-dimensional surface images is possible with specialized software applications. However, limited data exist concerning the accuracy of such volume calculations. The purpose of this study was to investigate the accuracy of breast volume calculations performed with the 3D BreAST, 3dMD Vultus, and VECTRA software applications.
METHODS: Twenty-six subjects who underwent 44 mastectomies were enrolled. Preoperative three-dimensional surface images were acquired with a VECTRA-XT stereophotogrammetry device. Breast volumes were calculated from these images with the three software applications. The mastectomy specimens were weighed to derive their actual volume and compared with the software calculations.
RESULTS: For all three methods, a positive correlation between the breast volume and absolute calculation error was found (p < 0.001), but not for the errors as a percentage of the breast volume (p = 0.17, p = 0.80, and p = 0.42). The 3D BreAST, 3dMD Vultus, and VECTRA applications provided mean volume calculation errors of 21, 186, and -32 ml (p = 0.27, p < 0.001, and p = 0.14) or 2 ± 25, 48 ± 26, and -6 ± 27 percent of the breast volume (p = 0.67, p < 0.001, and p = 0.16), respectively.
CONCLUSIONS: Despite that two applications calculated accurate mean breast volumes, all applications showed a high standard deviation in terms of the percentage of the breast volume. Therefore, the usefulness of absolute breast volume calculations from three-dimensional surface images seems limited. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, II.

Entities:  

Mesh:

Year:  2018        PMID: 29979363     DOI: 10.1097/PRS.0000000000004728

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  5 in total

1.  Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry.

Authors:  Yongwei Guo; Alexander C Rokohl; Friederike Schaub; Xiaoyi Hou; Jinhua Liu; Yue Ruan; Renbing Jia; Konrad R Koch; Ludwig M Heindl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-08-12       Impact factor: 3.117

2.  BreastGAN: Artificial Intelligence-Enabled Breast Augmentation Simulation.

Authors:  Christian Chartier; Ayden Watt; Owen Lin; Akash Chandawarkar; James Lee; Elizabeth Hall-Findlay
Journal:  Aesthet Surg J Open Forum       Date:  2021-12-11

3.  Surgery of congenital breast asymmetry-which objective parameter influences the subjective satisfaction with long-term results.

Authors:  Vivien Noisser; Andreas Eigenberger; Maximilian Weiherer; Stephan Seitz; Lukas Prantl; Vanessa Brébant
Journal:  Arch Gynecol Obstet       Date:  2021-09-03       Impact factor: 2.344

4.  Nonsubjective Assessment of Shape, Volume and Symmetry during Breast Augmentation with Handheld 3D Device.

Authors:  Zhouxiao Li; Thilo Ludwig Schenck; Riccardo Enzo Giunta; Lucas Etzel; Konstantin Christoph Koban
Journal:  J Clin Med       Date:  2022-07-11       Impact factor: 4.964

5.  "Three-dimensional evaluation of breast volume changes following autologous free flap breast reconstruction over six months".

Authors:  Floor N H Wilting; Marijn Hameeteman; Hanneke J P Tielemans; Dietmar J O Ulrich; Stefan Hummelink
Journal:  Breast       Date:  2020-02-10       Impact factor: 4.380

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.