Literature DB >> 29978833

Independent application of an analytical model for secondary neutron equivalent dose produced in a passive-scattering proton therapy treatment unit.

Kyle J Gallagher1, Phillip J Taddei.   

Abstract

The purpose of this study was to independently apply an analytical model for equivalent dose from neutrons produced in a passive-scattering proton therapy treatment unit, H. To accomplish this objective, we applied the previously-published model to treatment plans of two pediatric patients. Their model accounted for neutrons generated by mono-energetic proton beams stopping in a closed aperture. To implement their model to a clinical setting, we adjusted it to account for the area of a collimating aperture, energy modulation, air gap between the treatment unit and patient, and radiation weighting factor. We used the adjusted model to estimate H per prescribed proton absorbed dose, D Rx , for the passive-scattering proton therapy beams of two children, a 9-year-old girl and 10-year-old boy, who each received intracranial boost fields as part of their treatment. In organs and tissues at risk for radiation-induced subsequent malignant neoplasms, T, we calculated the mass-averaged H, H T , per D Rx . Finally, we compared H T /D Rx values to those of previously-published Monte Carlo (MC) simulations of these patients' fields. H T /D Rx values of the adjusted model deviated from the MC result for each organ on average by 20.8  ±  10.0% and 44.2  ±  17.6% for the girl and boy, respectively. The adjusted model underestimated the MC result in all T of each patient, with the exception of the girl's bladder, for which the adjusted model overestimated H T /D Rx by 3.1%. The adjusted model provided a better estimate of H T /D Rx than the unadjusted model. That is, between the two models, the adjusted model reduced the deviation from the MC result by approximately 37.0% and 46.7% for the girl and boy, respectively. We found that the previously-published analytical model, combined with adjustment factors to enhance its clinical applicability, predicted H T /D Rx in out-of-field organs and tissues at risk for subsequent malignant neoplasms with acceptable accuracy. This independent application demonstrated that the analytical model may be useful broadly for clinicians and researchers to calculate equivalent dose from neutrons produced externally to the patient in passive-scattering proton therapy.

Entities:  

Mesh:

Year:  2018        PMID: 29978833      PMCID: PMC6736632          DOI: 10.1088/1361-6560/aad1bc

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

Review 1.  Neutron dose and its measurement in proton therapy-current State of Knowledge.

Authors:  Roger Antoine Hälg; Uwe Schneider
Journal:  Br J Radiol       Date:  2020-01-21       Impact factor: 3.039

Review 2.  Determining Out-of-Field Doses and Second Cancer Risk From Proton Therapy in Young Patients-An Overview.

Authors:  Maite Romero-Expósito; Iuliana Toma-Dasu; Alexandru Dasu
Journal:  Front Oncol       Date:  2022-05-31       Impact factor: 5.738

3.  ANALYTICAL MODEL TO ESTIMATE EQUIVALENT DOSE FROM INTERNAL NEUTRONS IN PROTON THERAPY OF CHILDREN WITH INTRACRANIAL TUMORS.

Authors:  Kyle J Gallagher; Phillip J Taddei
Journal:  Radiat Prot Dosimetry       Date:  2019-06-01       Impact factor: 0.972

4.  Proton Radiotherapy Could Reduce the Risk of Fatal Second Cancers for Children with Intracranial Tumors in Low- and Middle-Income Countries.

Authors:  Kyle J Gallagher; Bassem Youssef; Rola Georges; Anita Mahajan; Joelle Ann Feghali; Racile Nabha; Zeina Ayoub; Wassim Jalbout; Phillip J Taddei
Journal:  Int J Part Ther       Date:  2021-02-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.