Literature DB >> 29978214

Transcutaneous Osseointegrated Implants for Pediatric Patients With Aural Atresia.

Elise Lippmann1, Cedric Pritchett2, Colleen Ittner3, Stephen R Hoff4,5.   

Abstract

Importance: Patients with aural atresia typically have maximal conductive hearing loss, which can have negative academic and social consequences. Transcutaneous osseointegrated implants (TOIs) can potentially restore hearing on the affected side.
Objectives: To review the demographic, audiological, and surgical outcomes of TOI placement in pediatric patients with aural atresia and to describe a modification in incision technique in anticipation of later auricular reconstruction. Design, Setting, and Participants: This retrospective case series reviewed 41 cases of TOI placement in pediatric patients between January 1, 2014, and September 30, 2016, at Lurie Children's Microtia and Aural Atresia Clinic. Patients, all younger than 18 years and with atresia or microtia, received at least 6 months of follow-up and underwent testing before and after surgery. Main Outcomes and Measures: Patient age, indication for procedure, ear sidedness, case length, incision type, complications, and other postoperative events. Audiological outcomes before and after implantation were measured using pure-tone averages and the Hearing In Noise Test for Children, presented in variable signal to noise ratios.
Results: In total, 46 TOIs were performed in 38 pediatric patients, but only 41 implantations in 34 patients were included in this study. Of the 34 patients, 13 (38%) were males and 21 (62%) were females, with a mean age of 8.9 (range, 5-17) years at the time of TOI placement. Microtia on the implanted side was present in 39 cases (95%). A modified posterior-superior scalp incision technique was used in 30 (73%) of 41 ears, all in cases of microtia. One perioperative surgical complication occurred: a seroma requiring drainage. Two patients developed minor skin irritation and erythema at the magnet site related to the overnight use of the processor, which resolved when removed while sleeping. The mean (SD; range) score for the Speech In Noise test at 5 dB signal to noise ratio improved from 75.3% (14.4%; range, 50%-92%) correct in unaided/preoperative condition to 93.6% (6.95%; range, 80%-100%) correct in the aided/postoperative condition. The mean improvement in score was 18.3% (95% CI, 10.8%-25.9%), with an effect size of 1.62 (95% CI, 0.95-2.29). The mean pure-tone averages (SD; range) similarly improved from 63.7 (13.2; range, 25-11) dB to 9.6 (4.9; range, 5-15) dB. Conclusions and Relevance: Transcutaneous osseointegrated implantation has a low complication rate among pediatric patients with atresia or microtia and can provide excellent audiological results. It should be included as a treatment option for this population of patients who meet audiological criteria.

Entities:  

Mesh:

Year:  2018        PMID: 29978214      PMCID: PMC6142998          DOI: 10.1001/jamaoto.2018.0911

Source DB:  PubMed          Journal:  JAMA Otolaryngol Head Neck Surg        ISSN: 2168-6181            Impact factor:   6.223


  20 in total

1.  Age-dependent effect of hearing loss on cortical inhibitory synapse function.

Authors:  Anne E Takesian; Vibhakar C Kotak; Dan H Sanes
Journal:  J Neurophysiol       Date:  2011-11-16       Impact factor: 2.714

2.  Patient Outcomes in Magnet-Based Implantable Auditory Assist Devices.

Authors:  Mallory B O'Niel; Christina L Runge; David R Friedland; Joseph E Kerschner
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2014-06       Impact factor: 6.223

3.  Clinical performance of a new magnetic bone conduction hearing implant system: results from a prospective, multicenter, clinical investigation.

Authors:  Robert Briggs; Andrew Van Hasselt; Michal Luntz; Marcos Goycoolea; Stina Wigren; Peter Weber; Henrik Smeds; Mark Flynn; Robert Cowan
Journal:  Otol Neurotol       Date:  2015-06       Impact factor: 2.311

4.  Bilateral bone-anchored hearing aid application in children: the Nijmegen experience from 1996 to 2008.

Authors:  Catharina A J Dun; Maarten J F de Wolf; Emmanuel A M Mylanus; Ad F Snik; Myrthe K S Hol; Cor W R J Cremers
Journal:  Otol Neurotol       Date:  2010-06       Impact factor: 2.311

Review 5.  Bilateral bone-anchored hearing aids for bilateral permanent conductive hearing loss: a systematic review.

Authors:  Renée M Janssen; Paul Hong; Neil K Chadha
Journal:  Otolaryngol Head Neck Surg       Date:  2012-06-19       Impact factor: 3.497

6.  Monaural deprivation disrupts development of binaural selectivity in auditory midbrain and cortex.

Authors:  Maria V Popescu; Daniel B Polley
Journal:  Neuron       Date:  2010-03-11       Impact factor: 17.173

7.  BAHA in children and adolescents with unilateral or bilateral conductive hearing loss: a study of outcome.

Authors:  Claudia Priwin; Radi Jönsson; Malou Hultcrantz; Gösta Granström
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2006-11-07       Impact factor: 1.675

8.  Binaural application of the bone-anchored hearing aid.

Authors:  A F Snik; A J Beynon; E A Mylanus; C T van der Pouw; C W Cremers
Journal:  Ann Otol Rhinol Laryngol       Date:  1998-03       Impact factor: 1.547

9.  Normal hearing is required for the emergence of long-lasting inhibitory potentiation in cortex.

Authors:  Han Xu; Vibhakar C Kotak; Dan H Sanes
Journal:  J Neurosci       Date:  2010-01-06       Impact factor: 6.167

10.  Effects of aural atresia on speech development and learning: retrospective analysis from a multidisciplinary craniofacial clinic.

Authors:  Daniel R Jensen; Lynn M Grames; Judith E C Lieu
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2013-08-01       Impact factor: 6.223

View more
  3 in total

1.  Osseointegrated device placement with minimally invasive surgery: Experience and audiological outcome.

Authors:  Ahmad M Aldhafeeri; Medhat Yousef; Farid Alzhrani
Journal:  Saudi Med J       Date:  2022-05       Impact factor: 1.422

2.  Audiological and subjective benefit with a new adhesive bone conduction hearing aid in children with congenital unilateral microtia and atresia.

Authors:  Yujie Liu; Chunli Zhao; Jinsong Yang; Peiwei Chen; Mengdie Gao; Danni Wang; Shouqin Zhao
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-11-24       Impact factor: 3.236

3.  Reconstruction of Congenital Microtia and Anotia: Analysis of Practitioner Epidemiology and Postoperative Outcomes.

Authors:  Nicholas G Cuccolo; Myrthe J Zwierstra; Ahmed M S Ibrahim; Abbas Peymani; Salim Afshar; Samuel J Lin
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-06-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.