Literature DB >> 29976106

Equine pericardium-covered stenting in post-traumatic pseudoaneurysm of cavernous internal carotid artery.

Jorge L Gonzalez-Cantero1,2, Mariano Del Valle Diéguez1, Cristina Monteserín Matesanz3, Javier Saura Lorente1, Francisco Villoria Medina1, Fernando Fortea Gil1, Enrique Castro Reyes1.   

Abstract

We report a case of traumatic intracranial carotid artery pseudoaneurysm treated with an equine pericardium-covered stent. The patient was admitted to the Emergency Department after sustaining severe polytrauma in a motor vehicle accident. A cavernous carotid pseudoaneurysm was detected after an episode of massive epistaxis that required emergent nasal packing. Treatment with parent vessel sacrifice was ruled out after an unfavourable balloon test occlusion. We opted for an equine pericardium-covered stent as a means to immediately seal the wall defect in the setting of massive bleeding secondary to an unstable lesion. We describe the potential benefits and drawbacks of these prostheses and the technical difficulties encountered in this particular case. To our best knowledge, this is the first published case report on a post-traumatic intracranial internal carotid artery pseudoaneurysm successfully treated with an equine pericardium-covered stent.

Entities:  

Keywords:  Epistaxis; equine pericardium-covered stent; pseudoaneurysm

Mesh:

Year:  2018        PMID: 29976106      PMCID: PMC6259351          DOI: 10.1177/1591019918785150

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  4 in total

1.  Traumatic aneurysms of cavernous internal carotid artery with secondary epistaxis.

Authors:  E F Chambers; A E Rosenbaum; D Norman; T H Newton
Journal:  AJNR Am J Neuroradiol       Date:  1981 Sep-Oct       Impact factor: 3.825

2.  Endovascular treatment of a mycotic intracavernous carotid artery aneurysm using a stent graft.

Authors:  Vivek Gupta; Vikash Jain; S N Mathuria; N Khandelwal
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

3.  Flow-diverter stenting in post-traumatic pseudoaneurysm of cavernous internal carotid artery with epistaxis.

Authors:  Andrea Giorgianni; Carlo Pellegrino; Renzo Minotto; Anna Mercuri; Fabio Baruzzi; Alfredo Cantoni; Larissa Nocchi Cardim; Luca Valvassori
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

4.  Massive epistaxis resulting from an intracavernous internal carotid artery traumatic pseudoaneurysm: complete resolution with overlapping uncovered stents.

Authors:  Fernando Ruiz-Juretschke; Enrique Castro; Olga Mateo Sierra; Begoña Iza; Jose Manuel Garbizu; Fernando Fortea; Francisco Villoria
Journal:  Acta Neurochir (Wien)       Date:  2009-04-07       Impact factor: 2.216

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.